Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T05BU00083
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/22/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Jim Watson DATE: April 22, 2005 Architect 3026 N. Country Club Road Tucson, Arizona 85716 SUBJECT: 6992 N. Centry Park Drive, Building No.5, Phase5 Grading Plan T05BU00083 (Second Review) T15S, R15E, Section 18 RESUBMITTAL REQUIRED: Grading Plan, Floood plain Use Permit and Drainage Statement. The Grading Plan (GP), Flood plain Use Permit (FUP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Please include a response letter to the comments along with the corrected copies of the GP. The response letter submitted was not sufficient. 2. The Grading plan cannot be approved prior to the approval of the Site plan. 3. List the area of disturbance on the plans. In square feet, not where the disturbance is occurring. 4. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Include a refuse enclosure detail. The call out for the "10'x10' clr. refuse area" does not ensure a 10' post to post clear area. Obtain permission from John Clark, Environmental Services @ 791-5543 x1136, for the placement of the dumpster or show the dumpster that will be used for this project. 5. Add to general notes: "All grading shall conform to chapter 11.0 of the COT Development Standards". 6. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed. Floodplain Use Permit: 1. The Flood plain use permit cannot be approved prior to the approval of the Site plan and Grading plan. Drainage Statement: 1. The Drainage Statement has been accepted by engineering. Stormwater pollution prevention plan: 1. Previously accepted Stormwater pollution prevention plan for all the phases of the project, must be available for review, at job site at all times. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/6992 E. Centry Park Dr. Grading 2 |
| 05/04/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Site plan (Case # T04CM05627) approval by all divisions is necessary to continue this review. |
| 05/09/2005 | KMEDINA1 | ZONING | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/09/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |