Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T04OT02225
Parcel: 12703514B

Address:
5745 E 5TH ST

Review Status: Completed

Review Details: REVISION - SITE

Permit Number - T04OT02225
Review Name: REVISION - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/13/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: April 12, 2005
ACTIVITY NUMBER: T04OT02225
PROJECT NAME: James A. Weaver Dentist Office
PROJECT ADDRESS: 5745 East 5th Street
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. Include a keynote description/legend on the site plan.

2. Show, label and give the sight distance (length) for the existing and future sight visibility triangles. For a PAAL to a Collector Street the sight distance for the near side is 265' and the far side is 110'. Revise accordingly. DS 2-02.2.1.A.10.

3. Show drainage patterns for the entire site. DS 2-02.2.1.A.16.

4. It appears that the solid waste truck will not clear the turning radius at the northwest side of the building. Demonstrate solid waste vehicle maneuverability fully dimensioned to the 90-gallon trash containers. Solid waste vehicles require 36' inside radius and 50' outside radius. It is recommended to contact John Clark from the Environmental Services Department for assistance, 791-3175 ext. 1136. DS 2-02.2.1.A.32.

5. Label the dimensioned 45' half ROW "Existing".

6. Dimension from street centerline to existing curb and sidewalk. DS 2-02.2.1.A.21.

7. Per the MS&R ROW Map the future ROW width is 45' from centerline for 5th Street. The future curb location is ten feet from the property line. This information must be included on the site plan. Show and label the future ROW width (45'), future curb and sidewalk location. DS 2-02.2.1.A.19.

8. Show existing topographic contours at intervals not exceeding 2 feet and/or spot elevations as pertinent and the Bench Mark based on the City of Tucson Datum, including City Field Book and page number. DS 2-02.2.1.A.23.
04/16/2005 PATRICIA GEHLEN ZONING REVIEW Denied CITY OF TUCSON DEVELOPMENT SERVICES DEPARTMENT
ZONING REVIEW SECTION

DATE: April 16, 2005
ACTIVITY NUMBER: T04OT02225-R
PROJECT NAME: James A. Weaver DDS
PROJECT ADDRESS: 5745 East 5th Street
PROJECT REVIEWER: Patricia Gehlen

The following items must be revised on or added to the site plan. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed:

1. This is a Board of Adjustment Review for a legal non-conforming site
2. Eliminate required loading zone (LUC 3.4.5.4),
3. Provide 14 excess parking spaces (per last approved site plan) which are compact (LUC 3.3.7.2.C.1) and don't meet minimum dimensions (LUC table 3.3.7-I),
4. Since new parking is being provided on two sides of the building, a raised concrete sidewalk must be provided on the north, east, and west sides of the building that meets DS 2-08 and connects to the existing sidewalk along the south side of the building (LUC 3.2.8.4.B),
5. Last approved site plan shows required five (5) foot landscape buffer on site but it is now in the public right-of-way (LUC 3.7.2.4.A.3).
04/18/2005 PATRICIA GEHLEN ZONING HC SITE REVIEW Denied Fully dimension handi-cap parking space prior to applying for BofA Variance.