Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T04OT01507
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/20/2004 | Loren Makus | ENGINEERING | REVIEW | Approved | January 3, 2005 (Special Inspection Required) The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: 8300 East Tanque Verde Road further described as the central portion of Lot 4 of Tanque Verde Country Estates recorded in Maps and Plats Book 9 Page 21 for the purpose of a constructing a commercial building. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions shall apply to this permit. 1. All work shall conform to the grading and improvement plans submitted as Activity Numbers T04BU01867 and T04CM4349 which are made part of this permit. 2. The building shall be placed on a engineered pad, compacted to 95% density, extending twenty-five (25) feet beyond the buildings foundation, unless a study prepared by a state-registered professional civil engineer and approved by the city engineer shows that a lesser distance is acceptable. 3. The lowest floor of the building in the property under this permit shall be placed a minimum of 2507.2 feet above mean sea level, NGVD 1929 (as referenced in the basis of elevation in the grading planT04BU01867), as Certified by a Registered Land Surveyor. This certification must be completed and returned to the Development Services Dept., Engineering Section on the 1st. Floor of the County/City Public Works Building at 201 N. Stone Avenue. Please call Development Services Department at 791-5550 or 740-6970 (IVR) for inspection prior to any wall construction. 4. The existing drainage patterns at the property lines shall not be obstructed. 5. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T04OT01507. For information please call 791-5550." 6. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 7. This permit becomes invalid and is subject to additional floodplain review, if any required development permit(s') changes the configuration of the structure and or site development. 8. Adhere to specifications outlined in Section C, C2 of the elevation certificate. 9. Return the elevation certificate to the Development Services Department, Engineering Division, 201 N. Stone Ave. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section. (EXPIRATION DATE) Month: 1 Day: 03 Year: 2005 Note: Final inspection or certificate of occupancy will be on hold until the Elevation Certificate is completed and returned to our office. The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/04/2005 | ANGIE SHOFFSTALL | APPROVAL SHELF | Completed |
| 02/04/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |