Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T04OT01494
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/08/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 02/25/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. (CODE SECTION/ DEVELOPMENT STANDARD) 1. Response acknowledged. Copy of recorded covenant to be provided. Previous comment remains: Per Pima County Assessors Records, the site is comprised of four (4) separate parcels which must be combined by providing a copy of the recorded City of Tucson Lot Combination Covenant. A copy of the City of Tucson Lot Combination Covenant is attached to the yellow site plan card. (D.S. 2-02.2.1.A.2) 2. Only note the project address under which the site plan is to be provided. Perimit application is filed under 6329 S. Fontana Avenue. Remove all other addresses noted on the site plan. Previous comment: List the project address. (D.S. 2-02.2.1.A.3) 3. Under general note 10, where the height is noted correct exclamation mark to number one (1). (D.S. 2-02.2.1.A.6) 4. Provide a copy of the site plan submitted for first review as requested. Previous comment may not be verified for compliance and remains: Mobile home number one (1) does not meet the street perimeter yard setback of 20 feet required by LUC Sec. 3.2.6.5.B.1. (D.S. 2-02.2.1.A.7) 5. Provide a copy of the site plan submitted for first review as requested. In addition, provide documentation of City of Tucson approved right-of-way abandonment. Previous comment may not be verified for compliance and remains: Mobile homes 15, 16, 19, 20, and office 27 do not meet the minimum 10-foot perimeter yard setback required. 7. Provide a copy of the easement to be recorded. A hold on the CofO will be placed on this project until the easement has been recorded and the requested information has been added to the plan. Previous comment: If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference. (D.S. 2-02.2.1.A.20) 8. Per direction of Patricia Gehlen, all mobile homes are to be provided with direct vehicular access. Vehicular access is required to units 11, 12, 15, 16, 19, 20, office 27, and both existing residences. 9. If a variance or LDO is applied for, please add a general note, which lists the following: case number, date of approval, variances granted, and conditions imposed. (D.S. 2-02.2.1.A.38) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/03/2005 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 03/03/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |