Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T04OT01147
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/18/2004 | JIM TATE | ENGINEERING | REVIEW | Denied | DATE: June 17, 2004 ACTIVITY NUMBER: T04OT01147 PROJECT NAME: Olsen Condominiums PROJECT ADDRESS: 3109 N. Olsen Ave. PROJECT REVIEWER: James C. Tate, P.E., CFM Resubmittal Required: Flood Use Permit Application, Grading Plan The following items must be corrected. 1. A copy of the stamped approved Tentative Plat must be included with the Grading Plan submittal. 2. A Flood Use Permit is required prior to Grading Plan approval. 3. Structures located in a floodplain must be elevated one foot above the 100-yr. peak WSEL. The floodplain ordinance (Tucson Code Chapter 26) defines structures as anything with walls and/or a roof. The attached garages are structures and must be elevated. The plan shows the FFE of these garages to be less than one ft. above the base flood. Re-design and properly elevate the garages. 4. Please note that all machinery and/or equipment (furnaces, hot water heaters, heat pumps, air conditioners, etc) must be elevated one foot above the base flood. Tucson Code Chapter 26 Section 5.2 5. In floodplain areas where fill is to be used to raise the elevation of a building site, the building line must be located not less than twenty-five feet land ward from any edge of the fill, unless a study prepared by a registered professional civil engineer shows a lesser distance is acceptable. Tucson Code Chapter 26, Sec 8(d) |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/06/2004 | LISA LESNY | OUT TO CUSTOMER | Completed |