Permit Number: T04OT00774
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T04OT00774
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/30/2004 Andrew Connor LANDSCAPE REVIEW Denied 1. A 6' wall is required to screen the loading zone from 12th St. per LUC Table 3.7.2-I. A 30" screen wall is indicated on landscape plan revise as necessary.
08/06/2004 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Site plan cannot be approved until Lot Combination recordation is complete with Pima County. D.S. 2-02.2.1.A.2

2. Indicate existing and proposed lot dimensions and bearings. D.S. 2-02.2.1.A.5

3. Graphically indicate location of downspouts and sidewalk scuppers on Site Plan. Indicate symbol in legend. Label scuppers on Site Plan as indicated on Figure 5 of Drainage Statement. Indicate a dimensioned detail of downspout. D.S. 2-02.2.1.A.6

4. Correct and revise arrow/text identifying proposed lot lines.

5. Indicate existing and proposed spot elevation symbols in legend.

6. Text too small on Sheet C03.01. Correct and revise.

Drainage Report
1. Indicate on page labeled "Retention Volume Calculations", ", detail "Weir Detail" and note "Retention volume required=1,500 ft" and "Note: The retention volume is taken from the bottom elevation to the weir elevation." From page labeled "Retention Basin Detail".

2. Submit percolation test.
08/23/2004 DAN CASTRO HANDICAP-SITE REVIEW Denied Refer to Zoning Review comments
08/23/2004 Daniel Castro ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next
Submittal, which states how all Zoning Review Section comments Regarding the Land Use Code and Development Standards were Addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Cross access and cross parking agreement must be provided for this site. Prior to lot reconfiguration approval submit a copy of the agreement for Zoning Review. Once the agreement has been reviewed by the Zoning Review Section, the revised legal descriptions and cross access and parking agreement must be recorded. Upon recordation, provide a copy of the recorded legal descriptions and recorded cross access/parking agreement to the Zoning Review Section for DSD records. The site plan may not be approved until the lot reconfiguration has been approved. (D.S. 2-02.2.1.A.2)

2. Add lot dimensions and bearings to the site plan. (D.S. 2-02.2.1.A.5)

3. Clearly label the proposed locations of both Class I and Class II bicycle parking along with the number and type of spaces proposed. (D.S. 2-02.2.2.1.A.9) (D.S. 2-09)

4. Per D.S. 2-08.4.1.A, at least one (1) sidewalk must be provided to the building from each street on which the project has frontage. Provide an accessible pedestrian sidewalk from the on-site pedestrian circulation system to the 12th Street right-of-way. The minimum four (4) foot sidewalk should be located to minimize any conflict with vehicular access or loading zones. The proposed loading space for the Autozone does not allow for a continuous unobstructed pedestrian path for the vehicle parking spaces located along the west side of the building and out to the 12th Street right-of-way. (D.S. 2-02.2.1.A12)

5. The east right-of-way line along Plumer Avenue is shown at the curb location. Most right-of-way areas include the sidewalk area. Please re-check the total right-of-way for Plumer Avenue. Existing right-of-way information may be obtained by contacting the Maps and Records Section at 791-3115. (D.S. 2-02.2.1.A.19)

6. The existing flowage easement proposed for abandonment must be recorded prior to site plan approval. Please note the recording docket and page reference on the site plan upon recordation. (D.S. 2-02.2.1.A.20)

7. All requested changes must be made to the site and landscape plans.

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/09/2004 TAMI ACHONG OUT TO CUSTOMER Completed
09/09/2004 SUE REEVES REJECT SHELF Completed