Permit Number: T04OT00536
Parcel: 11928011C

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T04OT00536
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2004 Doug Williams ENGINEERING REVIEW Approved A grading permit is required prior to any site disturbance. Please complete and activate a grading permit application with Development Services Department Customer Service, and ensure the following items are included on the plan:

1. Depict the Q100 entering/exiting the parcel.
2. Include a copy of the drainage submittal with the grading permit application.
3. Depict realistic construction area grading limits (i.e tie in the alternate tile field grading limits with total disturbance area).
4. Clarify and darken contour lines and elevations for legibility (previous comment # 11).
5. Provide the building pad elevation, the lowest structural member elevation, and proposed driveway spot elevations.
6. Depict/label riprap thickness (minimum of 2 x D50).

When the above items are provided, an over-the-counter review may be arranged with me for grading plan review/approval. Please call me at 791-5550 ext. 1189 or email at Dwillia1@ci.tucson.az.us to schedule an appointment.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/06/2004 TAMI ACHONG OUT TO CUSTOMER Completed
04/30/2004 ANGIE SHOFFSTALL APPROVAL SHELF Completed