Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04OT00435
Parcel: 133371820

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T04OT00435
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/23/2004 Paul Machado ENGINEERING REVIEW Approved March 23, 2004

FLOODPLAIN USE PERMIT NO. T04OT00435
ADDRESS: 668 N. Arizona Estates Loop
PROPERTY OWNER'S NAME: Pepper Viner Development

The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as (legal description):

Lot 15 of Arizona Estates, Bk. 45, M&P at Pg. 96 for the purpose of constructing a driveway through an unnamed wash.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit. (Or refer to Chapter 26 page 35)

1. All work shall conform to the attached plans (Drainage Report/Statement) which are made part of this permit.

2. Any building shall be placed on a engineered pad, compacted to 95% density, extending twenty-five (25) feet beyond the buildings foundation, unless a study prepared by a state-registered professional civil engineer and approved by the city engineer shows that a lesser distance is acceptable.

3. The existing drainage patterns at the property lines shall not be obstructed.

4. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T04OT00435. For information please call 791-5550."

5. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

6. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

7. Adhere to specifications outlined in Section C, C2 of the elevation certificate.

8. Return of the completed elevation certificate must be submitted to the Records Department, 201 N. Stone Ave. prior the issuance of a Certificate of Occupancy.

9. Any walls to be constructed will require a separate Permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section.

(EXPIRATION DATE) Month: 03 Day: 23 Year: 2005
Note the final inspection or certificate of occupancy will be on hold until the Elevation
Certificate is completed and returned to our office.


APPLICANT NAME: Pepper Viner Development
ADDRESS: P.O. Box 30128
PHONE NO.: (520) 721-7964


________________________ _____
APPLICANT'S SIGNATURE DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/23/2004 LISA LESNY OUT TO CUSTOMER Completed
03/23/2004 SUE REEVES APPROVAL SHELF Completed