Permit Number: T04CM05547
Parcel: 110060760

Review Status: Completed

Review Details: SITE

Permit Number - T04CM05547
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/02/2005 Jim Egan FIRE REVIEW Approved
02/02/2005 ANDREW CONNOR NPPO REVIEW Approved
02/02/2005 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. A street landscape border, Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line bounding the site except for points of ingress-egress, refuse storage must be located behind required street landscape borders.

2. Within a vehicular use area, one (1) canopy tree is required for each10 motor vehicle parking and canopy trees must be evenly distributed throughout the vehicular use area. Every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per Additional trees are required for the vehicle use area per LUC 3.7.2.3.A.1.a
02/02/2005 PAUL MACHADO ENGINEERING REVIEW Denied To: IDC Inc. DATE: February 7, 2005
Norman Amy 3943 E. Monte Vista Drive
Tucson, Arizona 85712

SUBJECT: Monte Vista Apartments, 3943 E. Monte Vista Dr.
Site plan T04CM05547 (First Review)
T13S, R14E, Section 33

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement.

The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
3. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. Explain the "ADD" called out in the Cut/Fill boxes.
4. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
5. Show Development plan number (T04CM05547) on all sheets per D.S. 2-02.2.1.29.
6. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Show the 10'x10' post to post clear area required for the dumpster. Obtain permission from John Clark, Environmental Services @ 791-5543 x1136, for the location of the dumpster.
7. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01.
8. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
9. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable.
10. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.
11. List the consulting engineer and the owner/developer on the plans with the pertinent information.

Drainage Statement:
1. A Drainage Statement is required for parcels not affected by 100 year flows of 100 cfs, of more per S.M.D.D.F.M., chap. II, 2.1.3.
2. The content and format of the Drainage Statement should follow S.M.D.D.F.M., chap. II, 2.1.3.
3. Show the project address on the cover of the Drainage Statement.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/3943 E. Monte Vista Drive site
02/07/2005 DAVID RIVERA ZONING HC SITE REVIEW Approved
02/07/2005 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT: T04CM05547
3943 E. Monte Vista Drive
Monte Vista Apartments

TRANSMITTAL: 02/07/05

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Under the location map list the Section Township and Range. Also label the following street names, Grant Road, Palo Verde Avenue, and Columbus Boulevard. DS 2-02.2.1.A.4

2. Please submit a copy of the building elevations to verify building heights and design type. DS 2-02.2.1.A.6

3. Based on the preliminary review of the site plan the proposed building setbacks along the east and west property boundaries do not meet the minimum setback requirement of 15.9 feet. The setback is based on the greatest of 10 or ¾ the height of the structure. Based on the proposed height listed on the plan the minimum setback is based on ¾ the height of the structure, which equals 15.9 feet. DS 2-02.2.1.A.7

4. If applicable indicate the location of existing or proposed easements. DS 2-02.2.1.A.20

5. If applicable indicate the location of proposed freestanding lighting. The type, size of pole and location must be depicted and labeled on the plan. DS 2-02.2.1.A.25

6. Please provide permits and LDO/Variance document that allowed the construction of the seven and eight-foot high block walls on the perimeter of the property. See landscape reviewer comments related to landscape borders, screening and NPPO requirements. DS 2-02.2.1.A.27

The proposed location of the Dumpster enclosure will require that a Board of Adjustment variance be granted or the dumpster enclosure must be relocated. See additional comments by the Landscape Reviewer and Engineering Reviewer. DS 2-02.2.1A.32

7. Under the proposed use note list the subject to section applicable to this type of development. DS 2-02.2.1.A.31

8. Prior approvals, such as Development Review Board, Lot Development Option, Board of Adjustment, Historic District Advisory Board, and Historical Commission must be listed on the site plan. The type of approval, date, and conditions of approval must be listed for each approval. Copies of the approval letter must be included with the site plan.
DS 2-02.2.1.A.38

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents

Final Status

Task End Date Reviewer's Name Type of Review Description
02/10/2005 TAMI ACHONG OUT TO CUSTOMER Completed
02/10/2005 ANGIE SHOFFSTALL REJECT SHELF Completed