Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM05536
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 08/18/2005 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | T04CM05536 1. A Grading plan and permit are required. This project does not meet the exemption criteria of Development Standard 11-01.2.3. The drainage report exhibits indicate that fill will be placed in areas with slopes that exceed 20 per cent. Provide a complete grading permit submittal with a grading plan showing the extent of work and details describing the toe down and tie in for the bank protection. The plan must be drawn to scale and the specifications for the bank protection must be included in the drainage report or in a separate report provided by a registered professional engineer. The plan must also show the extent of the floodplain. 2. The drainage report indicates that the bank will be protected with gunnited rock riprap. Revise the drainage report to provide sizing and embedding details and design criteria for the bank protection. The design must be consistent with the flow velocities indicated in the drainage report. If you have any questions contact me at loren.makus@tucsonaz.gov or at 791-5550 ext 1161. Loren Makus, E.I.T. Senior Engineering Associate |
| 08/25/2005 | PETER MCLAUGHLIN | NPPO | REVIEW | Approved | |
| 08/25/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Passed | Landscaping will approve plan when the engineering division has completed its review. |
| 08/25/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Passed | Landscaping defers to engineering and zoning for SFR. |
| 09/17/2005 | TERRY STEVENS | ZONING HC SITE | REVIEW | Passed | see zoning comments |
| 09/17/2005 | TERRY STEVENS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Terry Stevens FOR: David Rivera Senior Planner Principal Planner PROJECT:T04CM05536 2601 W. Arthur Pl. New SFR Site Plan Transmittal date: 3rd Review 9-17-05 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The plans submitted do not meet the criteria required for a site plan. See attached site plan example and criteria required. Submitted plans must be legible If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/31/2005 | SUE REEVES | REJECT SHELF | Completed |
| 09/27/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |