Permit Number: T04CM05523
Parcel: 13339029D

Address:
9851 E KENYON DR

Review Status: Completed

Review Details: SITE

Permit Number - T04CM05523
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/25/2005 Jim Egan FIRE REVIEW Approved
02/03/2005 DAN CASTRO ZONING REVIEW Approved
02/04/2005 DAN CASTRO ZONING HC SITE REVIEW Passed
02/07/2005 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Revise or remove Note #2 form Sheet L-4. Areas indicated in approved ERZ -99-01 dated 9/22/99 are to be preserved as natural undisturbed open space.

2. Remove Inventory and Preservation Plan Note #9 on Sheet L-4 and General Note on Sheet L-7. If additional plants are found then revised preservation plan will be submitted with adjusted calculations.
02/07/2005 ANDREW CONNOR NPPO REVIEW Denied 1. Revise or remove Note #2 form Sheet L-4. Areas indicated in approved ERZ -99-01 dated 9/22/99 are to be preserved as natural undisturbed open space.

2. Remove Inventory and Preservation Plan Note #9 on Sheet L-4 and General Note on Sheet L-7. If additional plants are found then revised preservation plan will be submitted with adjusted calculations.
02/18/2005 PAUL MACHADO ENGINEERING REVIEW Denied To: John Hucko DATE: February 22, 2005
3861 N. First Ave.
Tucson, Arizona 85719

SUBJECT: 9851 E. Kenyon Drive
Site plan T05CM05523 (First Review)
T14S, R15E, Section 14

RESUBMITTAL REQUIRED: Site Plan, Drainage Report and Flood Plain Use permit.

The Site Plan (SP), Hydrology Report (HR) and Flood Plain Use Permit (FUP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. An Overlay Zone Application for an E.R.Z. review may be required and is included with the comments. Inquire with the zoning dept. for applicability.
3. The Estes wash listed in the TDOT web site as being Xeroiparian Intermediate Habitat and an Environmental Resource Zone. A Mitigation Plan is required when disturbing any area within the floodplain
4. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
5. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15.
6. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
7. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. List the fill as zero if there is no fill for this project.
8. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
9. List the consulting engineer and the owner/developer on the plans with the pertinent information.
10. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
11. A Stormwater pollution prevention plan (SWPPP) may be required depending on the area that is disturbed. Contact Paul P. Machado at 791-5550 x1193.


Floodplain Use Permit:
1. The FUP cannot be approved prior to the Site Plan and Hydrology Report.

Hydrology Report:
1. A Hydrology report is required for parcels affected by 100 year flows of 100 cfs, of more per S.M.D.D.F.M., chap. II, 2.1.2.
2. The content and format of the Hydrology report should follow S.M.D.D.F.M., chap. II, 2.1.3.
3. Show the project address on the cover of the Hydrology report.
4. Drainage patterns shall not be altered. Drainage must enter and exit the site in the same place and manner.
5. The Estes wash listed in the TDOT web site as being Xeroiparian Intermediate Habitat and an Environmental Resource Zone. A Mitigation Plan is required when disturbing any area within the floodplain


If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/ 9851 E. Kenyon Drive Site

Final Status

Task End Date Reviewer's Name Type of Review Description
02/23/2005 DELMA ROBEY OUT TO CUSTOMER Completed