Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T04CM05480
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/01/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Sevilla Investments Tucson, AZ 85719 (520) 405-7115 FROM: Peter McLaughlin Senior Planner FOR: David Rivera Principal Planner Development Services Dept. PROJECT: T04CM05480 Office/Warehouse Development 2140 E. Winsett St. Site Plan Review TRANSMITTAL: June 1, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Add a loading zone calculation to the plan specifying the number of loading zones required (0) and provided (0). Remove the reference to the size of the loading zone and to the Board of Adjustment variance application, which is not required for the proposed building of less than 1,500 square feet. LUC 3.4.5.2 DS 2-02.2.1.A.38 2. The handicap crosswalk may not be located within the 24-foot PAAL. Revise location of this h/c accessible connection to cross over the PAAL at a 90-degree angle and ramp up to the proposed sidewalk located along the west property line. Provide a detail of the h/c ramp indicating its dimensions and its maximum slope. LUC 3.2.8.4 DS 2-08.4.1 DS 2-02.2.1.A.12 3. The 17' total width of the handicap parking space and access aisle shown on the site plan drawing is not consistent with the detail, which shows a total of 16 feet (8'+ 8'). Revise to be consistent. ANS/IBC 4. Add a location map to the upper right hand corner of the site plan. DS 2-02.2.1.A.4 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 06/01/2005 | PETER MCLAUGHLIN | ZONING HC SITE | REVIEW | Denied | See zoning review comments. |
| 06/09/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | Comments not addressed from previous submittal. 1. Previous plans indicate a Prosopis / Acacia within the street landscape border. Revise plan to Include location of canopy tree per LUC 3.7.2.4. 2. Indicate square footage of landscape area and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g. 3. The planting plan and layout calculations will include the correct plant count per DS 2-06.2.2.A. Revise the planting plan (List) to include the correct amount of plants for the entire site. 4. Submit NPPO plan or Application for Exception per DS 2-15.0. |
| 06/09/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or Application for Exception per DS 2-15.0. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/24/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |