| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/29/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL FOR BOARD OF ADJUSTMENT VARIANCE ISSUE SEE COMMENT 1 TO: Sevilla Investments Tucson, AZ 85719 (520) 405-7115 FROM: Peter McLaughlin Senior Planner FOR: David Rivera Principal Planner Development Services Dept. PROJECT: T04CM05480 Office/Warehouse Development 2140 E. Winsett St. Site Plan Review (3rd review) TRANSMITTAL: April 29, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Add a loading zone calculation to the plan specifying the number of loading zones required and provided. LUC 3.4.5.3 requires one loading space with a dimension of 12 feet by 35 feet. From the statement in the calculations it is acknowledged that a Board of Adjustment variance application will be applied for. If a variance is approved for the deletion of the loading zone requirement, add the case number, the date of approval, what the variance was approved for and any conditions imposed. LUC 3.4.5.2 DS 2-02.2.1.A.38 2. The 17' total width of the handicap parking space and access aisle shown on the site plan drawing is not consistent with the detail, which shows a total of 16 feet (8'+ 8'). Revise to be consistent. ANS/IBC If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 04/29/2005 | PETER MCLAUGHLIN | ZONING HC SITE | REVIEW | Denied | See zoning review comments. |
| 05/02/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Previous plans indicate a Prosopis / Acacia within the street landscape border. Revise plan to Include location of canopy tree per LUC 3.7.2.4. 2. Indicate square footage of landscape area and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g. 3. The planting plan and layout calculations will include the correct plant count per DS 2-06.2.2.A. Revise the planting plan to include the correct amount of plants for the entire site. 4. Submit NPPO plan or Application for Exception per DS 2-15.0 |
| 05/02/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or Application for Exception per DS 2-15.0 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/11/2005 | BETH GRANT | OUT TO CUSTOMER | Completed |