Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM05477
Parcel: 11307410B

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM05477
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/19/2005 Neil Saunders BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project T04CM05477

Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

General Requirements

1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned.
2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes.

Site Plan

1. Indicate the location of gas, water, electric and sewer or septic line on the property, and where they enter the building. Provide the location of your water meter and septic system if it exists.

Floor Plan

1. Windows A1 and A2 must be tempered

Structural Plan

1. 6x8 beam at carport is inadequate for 8.25' of tributary load and span of 13'. Resize.
2. 6/A3 - Provide positive connection from porch ledger to wall framing.
3. Note 3/8" plywood on wall behind east porch storage room in order to provide a minimum lateral bracing.
4. 4/A2 - Post footing detail, show 12" minimum depth into undisturbed soil and 6" from grade to bottom of post.
5. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply. Provide bird boards at eaves.
6. Note that Wood sill plates shall be foundation grade redwood or pressure-treated wood per R320.

Plumbing and Electrical Plans

1. Water line: Provide the total fixture unit demand and maximum developed length.
2. Note on plan compliance with the water conservation requirements. Water closets, 1.6 gallons per flush, sinks and showerheads, 3 gallons per minute.
3. Note on plans that shower and tub / shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type.
4. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code.
5. At least one wall switch controlled light or outlet must be provided at outdoor entrances or exits per E3803.3.
6. Where ceiling fans are shown on the plans, provide a note indicating only approved outlet boxes shall be used, per E4001.6.

MODEL ENERGY CODE:

1. Call out on the plan the "U" values of the windows and doors in compliance with the energy calculations provided.


If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.
12/27/2004 GERRY KOZIOL WWM REVIEW Denied Needs waste water 8th floor review of exsisting connection to public sewer thru adj properties (Jt use?)

Final Status

Task End Date Reviewer's Name Type of Review Description
01/20/2005 BETH GRANT OUT TO CUSTOMER Completed
01/20/2005 ANGIE SHOFFSTALL REJECT SHELF Completed