Permit Review Detail
Review Status: Completed
Review Details: POST 3RD PARTY REVIEW
Permit Number - T04CM05441
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/02/2005 | Gerry Koziol | WWM | REVIEW | Approved | |
| 02/02/2005 | Andrew Connor | NPPO | REVIEW | Passed | |
| 02/08/2005 | DAVID RIVERA | ZONING | REVIEW | Denied | 02/08/05 Development Services Department Zoning Review Section David Rivera Senior Planner Comments: Zoning has reviewed the site and building plans but cannot approve them at this time. Zoning will re-review and if possible approve the site and building plans on the next submittal providing all comments have been addressed. The following LUC requirements must be addressed. Vehicular Use Areas. The following requirements apply to developments which provide more than four (4) motor vehicle parking spaces. A. Canopy Trees in Vehicular Use Areas. 1. Within a vehicular use area, one (1) canopy tree is required for each ten (10) motor vehicle parking spaces or fraction thereof. a. The canopy trees must be evenly distributed throughout the vehicular use area. Every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk). b. In areas where a required landscape border falls within the vehicular use area, up to 50% of the canopy trees may be counted towards both the minimum parking lot canopy tree requirement and the landscape border canopy tree requirement c. An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree. d. Structurally covered or underground motor vehicle parking spaces are not included in calculating the required number and location of canopy trees. B. As of this review date a process to allow primary access from an alley has been discussed and a resolution or determination will be made sometime next week. The determination may also require additional code requirements to be met. Some of the requirements will be discussed at the meeting. This plan has been reviewed for compliance and depending on the outcome of the meeting a review of the plans over the counter will be possible for zoning. Please call me on Tuesday of next week and I will have an answer. 791-5608 ext. 1181 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/09/2005 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 02/09/2005 | SUE REEVES | REJECT SHELF | Completed |