Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM05109
Parcel: 11005099B

Address:
4631 E GLENN ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM05109
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2004 Gerry Koziol WWM REVIEW Denied need 8th floor review of location of connection to public sewer (fronts 21" public sewer)
12/29/2004 Neil Saunders BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project T04CM05109

Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

General Requirements

1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned.
2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes.

Floor Plan

1. Cross reference window schedule to each window on floor plan.
2. Note location of attic access and size (22"x30").
3. Garage door must have a self closer. Note this.
4. Provide tempered glass in bedroom 1 bath if sill is less than 60" above finished floor surface.
5. Note and specify that shower enclosures shall have a minimum finished interior area of 1,024 square inches and shall be capable of encompassing a minimum 30" circle per 1994 UPC SEC. 410.0. All glass enclosures shall be tempered.
6. Identify ceiling heights in all areas on floor plan. If sloped ceiling, note average height.
7. Master bedroom and great room window/door's designations are unclear.
8. Specify each braced wall panel or note that structure is fully sheathed.
9. Permit not required for 6' or less patio wall.

Structural Plan

1. Provide post-footing detail. Note all dimensions including 12" below grade and 6" from grade to bottom of post.
2. Post footing for concrete column on foundation plan conflicts with left elevation notes.
3. Provide roof-framing plan showing trusses, headers and beams.
4. Truss B13 does not have the shape consistent with layout diagram nor does it reflect both point loads from MG06 and CG08.

Plumbing, Mechanical and Electrical Plans

1. Provide vent for master bath WC.
2. Size kitchen sink waste pipe.
3. Provide trap for bedroom 1 bath tub.
4. Gas line size inadequate for total Btu demand - 180,000 BTU is excessive for HW heater, 50,000 Btu is sufficient. Redo calcs per table 12-3 1994 UPC.
5. Clotheswasher = 6 f.u., hose bibs =3 each (p total), Total fixture units 30 f.u. Revise and provide total developed length.
6. Note on plans: Mechanical shall comply with 2003 IRC chapters 13 - 24.
7. Note on plan that all electrical work shall comply with 2003 IRC chapters 33 - 42.
8. Note that all smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup.
9. Some outlets are missing a circuit designation (bedrooms, range…). Provide.

MODEL ENERGY CODE:

1. Door U-value of .077 seems too small. Justify.

If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.

NOTE: As of 09/06/04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. All plans shall reference these codes.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/04/2005 DELMA ROBEY OUT TO CUSTOMER Completed