Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM05036
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2004 | Jim Egan | FIRE | REVIEW | Approved | |
| 11/18/2004 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal. 2. Indicate location map on site plan. D.S. 2-02.2.1.A.4 3. It appears that the south and southwest lot lines have been changed according to the approved Development Plan. Indicate correct lot dimensions and bearings. Correct and revise. D.S. 2-02.2.1.A.5 4. Indicate roof slope and location of downspouts. D.S. 2-02.2.1.A.6 Add note, "All roof spouts will be routed under any adjacent sidewalk." D.S. 2-08.3.1 & 4.1.E 5. If applicable, indicate location, type, size and height of existing and proposed signage. D.S. 2-02.2.1.A.13 6. Indicate drainage patterns and finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16 7. Indicate estimated cut and fill quantities. D.S. 2-02.2.1.A.17 8. If applicable, indicate all easements of record to be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20 9. Indicate location and orientation of existing major physical features, such as drainageways. D.S. 2-02.2.1.A.22 10. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.A.23 11. Indicate refuse container location, size and access thereto fully dimensioned. |
| 11/29/2004 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPP and landscape plans included in approved case #'s D01-038 or S01-0045 to continue review. |
| 11/29/2004 | Andrew Connor | LANDSCAPE | REVIEW | Denied | Submit NPP and landscape plans included in approved case #'s D01-038 or S01-0045 to continue review. |
| 12/16/2004 | Peter McLaughlin | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Epstein/ Fenton, LLC 4855 N. Shamrock Place 109 Tucson, AZ 85705 (520) 806-4000 FRPM: Peter McLaughlin Senior Planner Development Services Dept. FOR: Patricia Gehlen Principal Planner Development Services Dept. PROJECT: T04CM05036 Lot 13 Hacienda Del Sol Office Complex 2480 E. River Road Site Plan Review (1st review) TRANSMITTAL: December 17, 2004 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. The lot dimensions on the site plan sheets C-1 and C-2 do not match those shown on the final plat. Revise drawing accordingly. Further comments regarding setbacks may be required once the correct lot dimensions are shown. DS 2-02. 2.1.A.5 2. Revise the site plan label (below the drawing and to the left of the north arrow) on sheet C-2 to indicate that this is lot 13, not lot 12 of Hacienda del Sol Office Complex. DS 2-02.2.1.A.2 3. Show the layout of parking correctly on the drawings on C-1 and C-2, including the required handicap parking spaces and aisles per the approved tentative plat. DS 2-02.2.1.A.8 4. Add the 20-foot wide private storm drain easement and the recordation information (Docket 11948 Page 2096) to the site plan drawing per the final plat. DS 2-02.2.1.A.20 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 12/17/2004 | PETER MCLAUGHLIN | ZONING HC SITE | REVIEW | Denied | See zoning review comments. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/24/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |