Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM05034
Parcel: 115041320

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM05034
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/20/2004 TACHONG1 BUILDING-RESIDENTIAL REVIEW Needs Review
12/20/2004 David Rivera ZONING REVIEW Denied See comment on PERMITS PLUS for T04CM05033
12/20/2004 TACHONG1 WWM REVIEW Needs Review
12/20/2004 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: December 20, 2004
ACTIVITY NUMBER: T04CM05033/T04CM05034
PROJECT ADDRESS: 1327 North Park Ave.
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

The over the counter approval has been revoked due to the following required information is not on the Site Plan. Please contact Patricia Gilbert (791-5550 ext. 2206) for any questions regarding the following comments.

1. Park Avenue is a collector street on the Major Streets and Routes map with a 64' width, 32' from street centerline. Draw, dimension, and label existing and future right-of-way information which includes existing and future curb and sidewalks.

2. Existing and future sight visibility triangles must be drawn, dimensioned, and labeled. The near side length for a driveway to a collector street is 265'. And the far side length is 110'

3. Per Land Use Code section 3.2.14.3, the vehicular use area must be designed in a manner that prevents vehicles from backing out onto the street (MS&R Street).

The site plan must per revised to accommodate all parking spaces on site and provide for onsite maneuverability to prevent vehicles from backing out onto Park Avenue.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/22/2004 LISA LESNY OUT TO CUSTOMER Completed