| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/20/2004 | TACHONG1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review | |
| 12/20/2004 | David Rivera | ZONING | REVIEW | Denied | 12/20/04 Development Services Department Zoning Review Section David Rivera Senior Planner Comments: Please address the following comments and provide with the next submittal package a response letter stating how all reviewer's comments have been addressed. 1. Park Avenue is a collector street on the Major Streets and Routes map. Draw, dimension, and label exisitng and future right-of-way information which includes exisitng and future curb and sidewalks. 2. Existing and future sight visibility triangles must be drawn, dimensioned, and labeled. 3. Per Land Use Code section 3.2.14.3, the vehicular use area must be designed in a manner that prevents vehicles from backing out onto the street (MS&R Street). The site plan must ber revised to accomodate all parking spaces on site and provide for onsite maneuverability to prevent vehicles from backing out onto Park Avenue. 4. This development must be provided with five vehicle parking spaces. Draw, dimension, and label the required pasrking spaces. Note on the plan the number of vehicle spaces required and the number of spaces provided. (Parking for residential development is determined by the number of bedrooms per unit 2.25. and 2.5 = 5 spaces.) 5. Label the overall height of the two-story structure and also label the height to the midpoint of the gable. |
| 12/20/2004 | TACHONG1 | WWM | REVIEW | Needs Review | |
| 12/20/2004 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: December 20, 2004 ACTIVITY NUMBER: T04CM05033/T04CM05034 PROJECT ADDRESS: 1327 North Park Ave. PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN The over the counter approval has been revoked due to the following required information is not on the Site Plan. Please contact Patricia Gilbert (791-5550 ext. 2206) for any questions regarding the following comments. 1. Park Avenue is a collector street on the Major Streets and Routes map with a 64' width, 32' from street centerline. Draw, dimension, and label existing and future right-of-way information which includes existing and future curb and sidewalks. 2. Existing and future sight visibility triangles must be drawn, dimensioned, and labeled. The near side length for a driveway to a collector street is 265'. And the far side length is 110' 3. Per Land Use Code section 3.2.14.3, the vehicular use area must be designed in a manner that prevents vehicles from backing out onto the street (MS&R Street). The site plan must per revised to accommodate all parking spaces on site and provide for onsite maneuverability to prevent vehicles from backing out onto Park Avenue. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/22/2004 | LISA LESNY | OUT TO CUSTOMER | Completed |