Permit Number: T04CM04877
Parcel: 115020620

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T04CM04877
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2004 Andrew Connor NPPO REVIEW Passed
11/17/2004 TACHONG1 BUILDING-RESIDENTIAL REVIEW Needs Review
11/17/2004 TACHONG1 WWM REVIEW Needs Review
12/10/2004 Daniel Castro ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were
addressed. (CODE SECTION/ DEVELOPMENT STANDARD)

1. Please add the exterior building wall height for the addition to unit A on the elevation drawings provided.

2. Per LUC Sec. 3.2.6.4 perimeter yard BB, the building setback required for the Unit A addition from the east property line is based on the greater of, 10 feet or ¾ height of the exterior building wall measured from design grade. Lot Development Option (LDO) approval will be required to allow the proposed six (6) foot setback from the Unit A addition to the east property line. For information regarding the LDO process please contact Frank Podgorski at 791-5550 ext. 1145 (LUC 3.2.7.2) (LUC Sec. 3.2.6.3)

3. If a Lot Development Option is applied for, provide a copy of the decision letter with the plan resubmittal and list the following information on the site plan: 1) case number 2) date of approval 3) setback modifications granted 4) conditions imposed.

4. Revise the number of vehicle parking spaces required and provided from four (4) to five (5), revise the lot coverage calculation, and show the fifth on-site parking space on the plan. Unit A is comprised of three (3) bedrooms requiring 2.25 spaces and Unit B is comprised of six (6) bedrooms (sitting room is considered a bedroom per the definition in LUC Sec. 6.2.2.B) requiring 2.5 spaces. Total number of spaces required is 4.75 rounded to five (5). (LUC Sec. 3.3.4 Residential Use Group "multi-family dwellings") (LUC Sec. 3.3.3.8)

If you have any questions about this transmittal or would like to set an appointment to discuss this project, please call Dan Castro, (520) 791-5608 ext. 1180.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/15/2004 TAMI ACHONG OUT TO CUSTOMER Completed