| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2005 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Michael St.Paul FOR: Patricia Gehlen Planning Technician Principal Planner PROJECT: T04CM04592 3200 North Olsen Avenue SFR 1st Review TRANSMITTAL: January 5, 2005 DUE DATE: January 5, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. This plot plan is for a single-family residence (SFR) in the R-1 Zone with four bedrooms, as defined by the Land Use Code (LUC), on site. LUC Sec 2.3.4.2.A.1 & LUC Sec 6.2.2 2. The minimum font size for a site plan or plot plan is twelve point (12 pt) type. Please revise the font size for the site coverage calculations. 3. The wall heights for each wall facing a property line, including second floor walls, measured from ground level to the highest point, must also be listed under the Site Calculations. The minimum setback along interior lot lines is the greater of six feet (6') or two-thirds the height of the wall. The minimum setback along the front street is the greater of twenty feet (20') or the height. The side street setback is ten feet (10'). All of the setbacks on this plot plan are to measured from the property lines. Please revise the plot plan. It appears that the second floor wall heights may not meet the required setbacks along the west and front property lines. LUC Sec 3.2.3.1.B, LUC Sec 3.2.6.4 & LUC Sec 3.2.6.5.A |
| 01/11/2005 | David Witt | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T04CM04592 1/12/05 3200 N. OLSEN AVE. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2003 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. KEYED NOTE 1 / SP.1 ; CLARIFY "WILSON AVENUE". 2. KEYED NOTE 5 / SP.1 ; PLEASE INDICATE THE LOCATION OF THE WATER SERVICE LINE. TYPOed AS 4? 3. KEYED NOTE 6 / SP.1 ; INDICATE THE LOCATION OF THE 6' SITE WALL. ARE THERE ANY WALLS OVER 6' ? IF NOT, PLEASE REMOVE THE REFERENCE TO THE TALLER WALLS MENTIONED ON THE SP.1 THAT IS MARKED "NEED CALC'S. HERE". WHY IS THERE A NUMBER OF SITE PLANS? FLOOR PLANS: 1. PLEASE INDICATE THE LOCATIONS OF THE HANDRAILS. 2. HOW DOES THE WINDOW ABOVE THE BATH #2 TUB COMPLY WITH R308.4 ITEM 5? WHAT IS THE HEADER HEIGHT? HOW HIGH IS THE TUB STANDING SURFACE ABOVE THE FLOOR? IS THERE 60" BETWEEN THE TUB'S STANDING SURFACE AND THE BOTTOM EDGE OF THE GLASS? IS TEMPERED NECESSARY? STRUCTURAL PLANS: 1. PLEASE LIST THE FLOOR LIVE AND DEAD LOADS USED. 2. PROVIDE MANUFACTURER'S CALCULATIONS AND DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS CALCULATIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS. ALSO, THE ENGINEER OF RECORD SHALL REVIEW AND "SHOP DRAWING" STAMP APPROVAL ON TRUSS CALCULATIONS. (FLAT BOTTOM TAPERED WOOD TRUSSES) 3. SPECIFY LATERAL SUPPORT OF TRUSSES. (FLAT BOTTOM WOOD TRUSSES) 4. PLEASE NOTE SPECIAL INSPECTIONS ARE REQUIRED FOR THE POST TENSIONED FOUNDATION AND THE 3000 P.S.I. CONCRETE IN THE AMVIC WALLS. SECTIONS - DETAILS - MISC. NOTES: 1. A / A.4 ; DETAIL 2 / D.1 SHOWS A NON-BEARING CONDITION vs. BEARING. PLEASE CO-ORDINATE. 2. D / A.4 ; DETAIL 1 / D.1 SHOWS A BEARING CONDITION vs. NON-BEARING. PLEASE CO-ORDINATE. 3. GENERAL NOTE 1 / A.5 ; THE CODE OF REFERENCE SHOULD BE THE 2003 I.R.C. 4. 2 / D.1 ; PLEASE SPECIFY SAG RESISTANT GYP BOARD ON THE CEILINGS THAT ARE FRAMED @ 24" O.C. SEE TABLE 702.3.5 FOOTNOTE D . 5. 5 / D.1 ; PLEASE SPECIFY THE BLOCK TO BEAM CONNECTION. 6. 6 / D.1 ; DID YOU MEAN FOR THE POST CAP FOR THE BEAMS CONTINUING ACROSS A MID-SPAN POST TO BE A "PC" vs. AN "EPC"? 7. 15 / D.1 ; PLEASE SPECIFY P.T. FOR THE WOODEN PLATES BEARING ON THE CONCRETE. PLUMBING PLAN: 1. RISER DIAGRAM 1 / P.1 ; PLEASE CHECK THE LENGTH OF THE TRAP ARM FROM THE VENT TO THE TRAP OF THE TUB IN BATH #1. SEE TABLE 10-1 IN THE U.P.C. 2. THE WATER DISTRIBUTION APPEARS TO BE UNDER SIZED PER THE U.P.C. I DIDN'T CHECK THE WHOLE SYSTEM. ALSO, CONSIDER THE LIFT OF THE WATER COLUMN. 3. AN "APPEAL TO THE BUILDING OFFICIAL" IS REQUIRED TO USE THE PLUMBING FROM THE I.R.C. 4. PLBG. SPECIFICATIONS AND NOTES, 7.2, B / P.1 ; HANK….. "FLUSH" ? 5. PLEASE ILLUSTRATE THE WATER HEATER'S P & T LINE ROUTE. 6. HOW DOES THE WATER HEATER'S FLUE EXIT THE BUILDING? 7. PROVIDE COMBUSTION AIR FOR THE WATER HEATER. SEE THE STATE PLUMBING CODE, THESE ARE THE AMENDMENTS TO THE U.P.C., TABLE A IN CHAPTER 5. THE I.R.C. CAN BE USED ON APPEAL TO THE BUILDING OFFICIAL. ELECTRICAL PLANS: 1. PLEASE PROVIDE LIGHTING AT DOOR "D24", NOOK / PORCH. SEE E3803.3. 2. PROVIDE ARC-FAULT PROTECTION FOR THE BEDROOM OUTLETS. SEE E3802.11 . 3. PLEASE NOTE LIGHT FIXTURES LOCATED OVER TUBS AND SHOWERS ARE REQUIRED TO BE LISTED AS APPROVED FOR USE IN WET AREAS. SEE E3903.8 . 4. RISER DIAGRAM / E.1 ; PLEASE ILLUSTRATE THE HEIGHT OF THE CENTER LINE OF AN ELECTRIC METER SOCKET OF 3'-6" TO 6'-3". SEE T.E.P.'S SR-405 MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
| 12/20/2004 | Gerry Koziol | WWM | REVIEW | Denied | need 8th floor credit evaluation |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/13/2005 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 01/13/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |