Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM04562
Parcel: 126161720

Address:
320 S BRYANT AV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T04CM04562
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/01/2004 GERRY KOZIOL WWM REVIEW Approved
11/08/2004 DAN CASTRO ZONING REVIEW Approved COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were
addressed. (CODE SECTION/ DEVELOPMENT STANDARD)

1. Elevation drawing shows a 14'03" height to the mid-point of the roof of the proposed accessory structure. Per LUC Sec. 3.2.5.3.B, accessory structures shall not exceed twelve (12) feet in height, unless attached to a principal structure. If attached to a principal structure, maximum height permitted is the same as for the principal structure.

2. Review of this plan by the Zoning Review Section may be done over the counter. Please contact Dan Castro to set an appointment.

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
11/12/2004 Neil Saunders BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project T04CM04562

Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

General Requirements

1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned.
2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes.

Floor Plan

1. Show that each water closet is located in a clear space not less than 30" wide and has a clear space in front not less than 21" per figure R307.2.

Foundation Plan

1. Provide landing at door per R311.

Structural Plan

1. Footing detail - Show width of footing and minimum depth into undisturbed soil (12").
2. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply.
3. Provide lintel for evap cooler opening.

Plumbing, Mechanical and Electrical Plans

1. Specify waste pipe material.
2. Water line: Provide the total fixture unit demand and maximum developed length.
3. P&T line is a min. ¾" copper.
4. Note on plan compliance with the water conservation requirements. Water closets, 1.6 gallons per flush, sinks and showerheads, 3 gallons per minute.
5. Note on plans that shower and tub / shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type.
6. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code.
7. Note on plans: Mechanical shall comply with 2003 IRC chapters 13 - 24.
8. Return air ducts are not allowed in bathrooms or utility rooms per M1602.2.
9. Note U values for windows. (max is 1.28)

If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/12/2004 ELAINE ROSE OUT TO CUSTOMER Completed
11/12/2004 ANGIE SHOFFSTALL REJECT SHELF Completed