Review Date Reviewer's Name Type of Review Description Status Comments
11/05/2004 Jim Egan FIRE REVIEW Approved
11/18/2004 ANDREW CONNOR NPPO REVIEW Passed
11/18/2004 Andrew Connor LANDSCAPE REVIEW Passed
11/18/2004 PETER MCLAUGHLIN ZONING HC SITE REVIEW Approved
11/18/2004 PETER MCLAUGHLIN ZONING REVIEW Denied TO: Sally Lopez
6840 S. Tucson Blvd.
Tucson, AZ 85716
(520) 741-7501

FROM: Peter McLaughlin
Senior Planner
Development Services Dept

FOR: PATRICIA GEHLEN
Principal Planner
Development Services Dept.
PROJECT:
T04CM04543
Parking lot canopy/attendant booth
General Manufacturing Use
6850 S. Tucson Blvd.
Site Plan Review (1st review)

TRANSMITTAL: November 18, 2004

Upon completion of the following revisions/additions, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following item must be revised on or added to the site plan:

1. This project is being reviewed as a less than 25% building area expansion. Full code compliance is not required.
DS 2-02

2. Add the zoning and adjacent zoning (all P-I) to the site plan drawing. DS 2-02.2.1.A.28

3. The previously approved site plan appears to show a pedestrian connection between the building and the sidewalk along Tucson Blvd. Show this connection on the new site plan as required by DS 2-08.
DS 2-02.2.1.A.12

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
12/03/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Denied Depict and label near and far side sight visibility triangles (see penciled triangles - 20' x 345' near side, and 20' x 30' far side (pedestrian SVT), in accordance with Development Standards 2-02.2.1 A 10 and 3-01.5.0.

An over the counter approval/stamping may be arranged upon completion of all comments provided. Please contact me to schedule a time. I can be reached at 791-5550 ext. 1189 or email at Doug.Williams@tucsonaz.gov

Doug Williams
Sr. Engineering Associate
Engineering Division
Development Services Department