Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/NPPO
Permit Number - T04CM04474
Review Name: RESIDENTIAL BLDG/ZONING/NPPO
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/18/2004 | Andrew Connor | NPPO | REVIEW | Passed | |
11/08/2004 | Daniel Castro | ZONING | REVIEW | Approved | |
11/16/2004 | David Witt | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T04CM04474 11/16/04 2787 W. AVE. AZAHAR PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FLOOR PLANS: 1. PROVIDE THE FLOOR PLAN OF THE ADJACENT EXISTING ROOMS. 2. THE 3040 SH WINDOWS ARE TO SMALL FOR EGRESS. 24" NET CLEAR OPENING HEIGHT IS REQUIRED. SECTIONS - DETAILS - MISC. NOTES: 1. 1 / 1 ; HOW IS AN ANCHOR BOLT INSTALLED IN EXISTING CONCRETE? DO YOU MEAN AN EXPANSION BOLT? 2. 1 / 1 ; WHAT IS A "INDUCTIVE" SOLE PLATE? 3. PROVIDE A COMPLETE BUILDING CROSS-SECTION FROM THE FRONT WALL THROUGH THE STORAGE ROOM PARTITION AND THROUGH THE EXISTING WALL. SHOW AND DESCRIBE THE ROOF THROUGH THE EXISTING FOUNDATION. ARE THE EXISTING POSTS AND BEAMS TO BE REMOVED OR WILL THEY STAY? IS THE EXISTING CEILING INSULATED OR WILL INSULATION BE PROVIDED? WHAT IS THE EXISTING ROOF FRAMING? ELECTRICAL PLANS: 1. PROVIDE A RECEPTACLE WITHIN 6' OF THE DOOR ON THE WEST WALL. 2. DESCRIBE THE "NEW ELEC. FEED". IS IT A SUB- PANEL? IF SO, WHAT AMPACITY? 3. A SWITCHED SOURCE OF LIGHT IS REQUIRED ON THE OUTSIDE OF THE BEDROOMS EXIT DOOR. IS IT EXISTING OR WILL IT HAVE TO BE ADDED? MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/23/2004 | BETH GRANT | OUT TO CUSTOMER | Completed |
11/23/2004 | SUE REEVES | REJECT SHELF | Completed |