Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM04354
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/06/2004 | Jim Egan | FIRE | REVIEW | Approved | |
| 10/12/2004 | ANDREW CONNOR | NPPO | REVIEW | Denied | 1. Submit any previously approved NPP plans for phased development. 2. Indicate on the NPP plan all plants within development area to be salvaged and removed from the site per DS 2-15.3.4.A 3. Remove reference to Pima County included in on site monitoring note on sheet 9 of 15 the site is subject to CITY OF TUCSON LAND USE CODE Sec. 3.8.6.7.D. On-Site Monitoring. |
| 10/12/2004 | Andrew Connor | LANDSCAPE | REVIEW | Denied | 1. Submit any previously approved NPP plans for phased development. 2. Indicate on the NPP plan all plants within development area to be salvaged and removed from the site per DS 2-15.3.4.A 3. Remove reference to Pima County included in on site monitoring note on sheet 9 of 15 the site is subject to CITY OF TUCSON LAND USE CODE Sec. 3.8.6.7.D. On-Site Monitoring. 4. All disturbed areas shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7 Include treatment for raked earth areas indicated in layout and construction note #9 on sheet 6 of 19. |
| 10/13/2004 | Peter McLaughlin | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Joe O'Neill 900 S. Randolph Way Tucson, AZ 85716 (520) 791-4873 FROM: Peter McLaughlin Development Services Dept. FOR: Patricia Gehlen Principal Planner Development Services Dept. PROJECT: T04CM04354 Purple Heart Park Expansion 9800 E. Rita Road Road Site Plan Review (1st review) TRANSMITTAL: October 14, 2004 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan is being reviewed as a less than 25 % expansion. Please provide a copy of the last approved site plan with the next submittal. 2. Specify in the vehicle parking calculations (under the site information on sheet 2 of 19) the number of parking spaces required and provided with the proposed improvements. Include calculations for handicap parking required/provided. Vehicle parking is based on the number of athletic fields (15 parking spaces required per soccer field). Bicycle parking is required at a rate of 15% (all class 2) of the vehicle parking provided. DS 2-02.2.2.A.4 DS 2-02.2.1.A.8 3. Dimension the proposed parallel parking spaces in a parking typical at the required 23 feet by 8 feet. DS 2-02.2.1.A.8 4. Show the location of and provide a fully dimensioned layout for any new bicycle parking proposed. Also, indicate the specific type of rack and the number of bicycles it supports. DS 2-09.6.0 5. Revise the current site zoning on the sheet 1 of 19 to read RX-1 rather than SR, and revise the development designator to read "9" instead of "6". DS 2-02.2.1.A.28 6. Revise the legal description in the location map as no part of the site is within the northwest corner of Section 23, T-15S, R 15 E. DS 2-02.2.1.A.2 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 10/14/2004 | PETER MCLAUGHLIN | HANDICAP-SITE | REVIEW | Denied | See zoning comment #2 regarding handicap parking. |
| 10/25/2004 | Loren Makus | ENGINEERING | REVIEW | Denied | DATE: October 27, 2004 TO: Joe O'Neill, Tucson Parks and Recreation SUBJECT: Purple Heart Park, Site Plan Review REVIEWER: Loren Makus ACTIVITY NUMBER: T04CM04354 SUMMARY: The Site Plan was reviewed by Development Services Department Engineering Division. The Site Plan was not approved at this time. The Drainage report is approved for purposes of this site plan only. Include a copy of the drainage report with future submittals. Site Plan comments: 1. Revise the note on sheet 2 to correctly state the extent of the area of improements. The area within the grading limits appears to exceed one acre. If the area within the grading limits exceeds one acre a stormwater pollution prevention plan will be required with the grading permit application. 2. A complete grading permit application is required for this project. Revise the Site Plan to address all of these comments. If you would like to meet with me to discuss any of these comments please call me at (520) 791-5550 ext. 1161. Loren Makus, E.I.T. Senior Engineering Associate Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/10/2004 | DELMA ROBEY | OUT TO CUSTOMER | Completed |