Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T04CM04340
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/30/2004 | Andrew Connor | NPPO | REVIEW | Passed | |
| 10/05/2004 | Gerry Koziol | WWM | REVIEW | Approved | |
| 10/14/2004 | Daniel Castro | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. (CODE SECTION/ DEVELOPMENT STANDARD) 1. Please note the exterior building wall heights on the site plan (sheet S-1) as follows: Maximum height of new structure(s) = ____ Height of exterior walls for new addition(s): North: ____ feet high South: ____ feet high East: ____ feet high West: ____ feet high Exterior building wall heights are to be measured from design grade elevation. The elevation drawing (sheet A-2) submitted shows building elevation heights that are measured from finished floor elevation. Setback requirements may not be verified for compliance until the height is provided from design grade to the highest point of the exterior building wall and listed on the site plan. It does appear that the east and west perimeter yard setbacks are not in compliance with the requirements listed under LUC Sec. 3.2.6.4 perimeter yard indicator "AA". The building setback required is based on the greater of: "6' or 2/3 height of exterior building wall." A Lot Development Option (LDO) will be required to allow the required building setback to be reduced. For information regarding the LDO process please contact Frank Podgorski at 791-5550 ext. 1145 (LUC 3.2.7.2) (LUC Sec. 3.2.6.3) 2. This project contains a total of seven (7) bedrooms as defined by LUC Sec. 6.2.2 (bedroom definition). Seven (7) bedrooms will require five (5) vehicle parking spaces to be provided as described in below comment number three (3). (LUC Sec. 3.5.7.1.G) 3. For all single family dwellings in the R-1 zone with five or more bedrooms, all parking and maneuvering must be located on-site, either in a side or rear perimeter yard. The vehicular use area must be improved, which includes surfacing, striping, and provisions of barriers in conformance with Development Standard 3-05.0. Vehicle parking spaces may not be located in a vehicular use area in any front street perimeter yard. Tandem parking is not allowed. (LUC Sec. 3.5.7.1.H) 4. A City prepared covenant, which will run with the land, will be required for this site. The covenant's purpose is to prevent any bedroom from being leased separately. The covenant must be recorded and a copy provided to the Zoning Review Section for DSD records. Please contact me to receive a copy of the covenant. 5. If a Lot Development Option is applied for, provide a copy of the decision letter and list the following information on the site plan: 1) case number 2) date of approval 3) setback modifications granted 4) conditions imposed. If you have any questions about this transmittal or would like to set an appointment to discuss this project, please call Dan Castro, (520) 791-5608 ext. 1180. |
| 10/20/2004 | LLESNY1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/20/2004 | LISA LESNY | OUT TO CUSTOMER | Completed |