Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T04CM04298
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/26/2004 | EGRANT1 | WWM | REVIEW | Passed | |
| 12/27/2004 | Neil Saunders | BUILDING-RESIDENTIAL | REVIEW | Denied | Plan Check Comments - Project T04CM04298 Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. General Requirements 1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned. 2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes. 3. All plans shall comply with 2003 IRC (less plumbing plans). Revise all notes and references. Floor Plan 1. Note and specify that shower enclosures shall have a minimum finished interior area of 1,024 square inches and shall be capable of encompassing a minimum 30" circle per 1994 UPC SEC. 410.0. All glass enclosures shall be tempered. 2. Show that each water closet is located in a clear space not less than 30" wide and has a clear space in front not less than 21" per figure R307.2. 3. Window adjacent exterior bedroom door needs to be tempered. Within 24" or door per R308.4. Structural Plan 1. For comments 2 and 3 below specify which hole is which. 2. Provide access to each separate attic space that exceeds 30SF per R408.3 and R807. Designate locations on the drawings. Openings shall not be less than 22"X30" for attics. Attic access shall provide a minimum of 30" of headroom, and shall be located in a hallway or readily accessible space. 3. Specify and detail all over-framing. If solid sheathing is used on the lower trusses, provide minimum openings of 22" by 30" for access and ventilation into over-framed areas (>30 S.F.). If solid sheathing is not used on lower trusses, provide details for bracing of top chord of lower trusses. 4. Complete attic vent calcs. Note required and provide ventilation areas. 5. Elevations and sections callout double red brick while the details are for 8" CMU and light frame/veneer construction. Clarify. 6. If brick veneer is used (detail C) how will this structure comply with R602.10? Braced walls. 7. Section B - Dimension 12" into undisturbed soil, 6" from grade to post and a post base rated for uplift (ABA46). 8. Size wood header over bedroom door. 9. 2&3/5 - Provide bond beam at top of CMU wall per R606.10(2). MODEL ENERGY CODE: 1. Call out on the plan the "R" values of insulation and show how CMU wall will meet R-13. If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/13/2005 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 01/13/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |