Permit Number: T04CM04237
Parcel: 12703040B

Review Status: Completed

Review Details: SITE

Permit Number - T04CM04237
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/26/2004 Jim Egan FIRE REVIEW Denied Fire sprinklers required per 2003 IBC Sec. 902.2.1.2 (Tucson Amendment).
10/27/2004 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal.

2. Indicate legal property description. D.S. 2-02.2.1.A.2

3. Indicate all existing buildings and structures, including roof slope and location of downspouts. D.S. 2-02.2.1.A.6 Add note, "All roof spouts will be routed under any adjacent sidewalk." Sidewalks shall be flood free for all storm discharges of up to a ten (10) year flood event. Indicate roof direction/drainage. D.S. 2-08.3.1 & 4.1.E

Clearly identified vehicular and pedestrian circulation. Show dimension for driveways, sidewalks, pathways and PAALs. D.S. 2-02.2.1.A.12

4. Indicate drainage patterns, proposed finish floor elevation(s) and finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16

5. Dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. D.S. 2-02.2.1.A.19
11/02/2004 ANDREW CONNOR NPPO REVIEW Approved Exception
11/02/2004 Andrew Connor LANDSCAPE REVIEW Denied On sites where the gross floor area of the existing building(s) is ten thousand (10,000) square feet or less, expansions in square footage of land area, floor area, lot coverage, or vehicular use area as follows:

a. If the expansion is less than fifty (50) percent, the requirements of this Division apply only to the proposed expansion. Existing development on the site is subject to the zoning regulations in effect at the time the existing development received zoning approval.

b. If the expansion is fifty (50) percent or greater or if expansions as of February 15, 1991, cumulatively result in a fifty (50) percent or greater expansion in land area, floor area, lot coverage, or vehicular use areas, the requirements of this Division apply to the entire site.

Include previous expansion calculations with re-submittal per LUC 3.7.1.2.B.2
11/22/2004 Elizabeth Eberbach HANDICAP-SITE REVIEW Denied 1. The last approved site plan from 1999 shows all vehicle parking spaces at a 90 degree angle. The new site plan submitted shows angle parking spaces. Provide the degree of angle, space dimensions, and PAAL widths for all angle parking spaces including disabled parking spaces and access aisles or a typical detail for both may be provided. Refer to LUC Table 3.3.7-I for motor vehicle area dimensions. This information is required since the parking lot configuration has changed from the last time the site was reviewed by the City in 1999 and has never been verified for L.U.C. compliance. (D.S. 2-02.2.1.A.8)

2. Provide disabled access ramp/s where required and provide a detail of the access ramp. (ICC/ANSI A117.1-2003 Section 405) (D.S. 2-02.2.1.A.12)
11/23/2004 Daniel Castro ZONING REVIEW Denied COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code (L.U.C.) and Development (D.S.) Standards were addressed. This review is based on a 14.6% building area expansion, which results in a full code compliance review for the expansion area only.

1. List the legal description of the property. (D.S. 2-02.2.1.A.2)

2. Add lot dimensions and bearings. (D.S. 2-02.2.1.A.5)

3. The last approved site plan from 1999 shows all vehicle parking spaces at a 90 degree angle. The new site plan submitted shows angle parking spaces. Provide the degree of angle, space dimensions, and PAAL widths for all angle parking spaces including disabled parking spaces and access aisles or a typical detail for both may be provided. Refer to LUC Table 3.3.7-I for motor vehicle area dimensions. This information is required since the parking lot configuration has changed from the last time the site was reviewed by the City in 1999 and has never been verified for L.U.C. compliance. (D.S. 2-02.2.1.A.8)

4. Please note the existing and proposed building heights on the site plan. In addition, label and dimension any canopies, overhangs, and use. (D.S. 2-02.2.1A.6)

5. Provide disabled access ramp/s where required and provide a detail of the access ramp. (ICC/ANSI A117.1-2003 Section 405) (D.S. 2-02.2.1.A.12)

6. Indicate the location of the existing loading zone, provide dimensions. (D.S. 2-02.2.1.A.14)

7. A minimum five (5) foot distance for a pedestrian refuge area must be maintained between the new building area and the PAAL (D.S. 3-05.2.2.B.1). Within this pedestrian refuge area a minimum four (4) foot wide sidewalk is required and shall show how it connects to the Jefferson Avenue right-of-way. (D.S. 2-02.2.1A.12)

8. Label the zoning classification of the adjacent parcels. (D.S. 2-02.2.1A.28)

9. Revise general note three (3) to state that the expansion area is to be reviewed for full code compliance.

10. Correct the square footage of the total building area listed under general note four (4) and eight (8) from 7,019 to 7,020 square feet.

11. Under general note five (5), revise the number of bicycle parking spaces to be based on the total number of vehicle parking spaces provided (73). (L.U.C. 3.3.3.5)

12. Under general note eight (8), correct the proposed F.A.R. to .15. (D.S. 2-02.2.2.A.3)

13. All requested changes must be made to the site and landscape plans.


If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/24/2004 LISA LESNY OUT TO CUSTOMER Completed