Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/NPPO
Permit Number - T04CM04163
Review Name: RESIDENTIAL BLDG/ZONING/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/07/2005 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 02/28/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Denied | Plan Check Comments - Project T04CM04163 Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. General Requirements 1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned. 2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes. Site Plan 1. Indicate the location of gas, water, electric and sewer or septic line on the property, and where they enter the building. Provide the location of your water meter and septic system if it exists. Structural Plan 1. Carport section B-B/ provide post bases rated for uplift (ABA, ABE, ABU). Dimension 6" from grade to post. 2. Detail A/ Dimension 6" from grade to sill plate, callout pressure treated plate, anchor bolt size and spacing, #4 rebar in continuos bond beam at top of stem wall. 3. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 PSF is being used per table R401.4.1 4. LPI 200 and 225 are no longer in production. Provide available I-joist specifications. Consider (9-1/2" LPI-18 @ 24" o/c for span A and 16" o/c for span B). 5. 6x8 beam is inadequate for middle carport span and tributary width. Resize (4x10 or 6x10). 6. 3/5 - Specify joist hanger. Also, Why is this condition optional? What is the other option? 7. Braced wall design - If structure is fully sheathed, note this. If not provide minimum braced wall panels per R602.10. 8. Provide tiedowns at northeast corner of family room addition. Alternate braced wall panel is a minimum of 32' with tiedowns at each end. 9. Will Glulam beam at kitchen/family room addition boundary be cantilevered from the "12x12 framed column" into the kitchen? Clarify structural conditions at this location. Specify cantilever length. MODEL ENERGY CODE: 1. NOTE: If addition is < 20% of total square footage of dwelling, you are not required to meet MEC requirements. 2. Provide energy calculations per the 1998 IECC and comply with IRC chapter 11. 3. Call out on the plan the "R" values of insulation, as well as the "U" values of the windows and doors in compliance with the energy calculations provided. If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113. NOTE: As of 09/06/04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. All model plans shall reference these codes. |
| 03/04/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. a) Please note the exterior building wall heights on the site plan sheet 1 as follows: Maximum height of new structure(s) = ____ Height of exterior walls for new addition(s): North: ____ feet high South: ____ feet high East: ____ feet high West: ____ feet high b) Building height shall be measured from design grade. 2. Dimension building wall heights on elevation drawings. 3. Dimension building setbacks from north property line and west property line to existing carport and guest house. In addition, provide a copy of the last approved site plan to verify that both of these structures have been permitted. You may check the records section for a copy of the approved site plans or permits. 4. Dimension building setback from west property line to new addition. 5. Tucson Blvd. is designated a major street by the Major Streets and Routes (MS&R) Plan with a total right-of-way of 76 feet. Please label and dimension the "existing" and "future" right-of-way and existing and future curb location for Tucson. Face of "future" curb will be located nine (9) feet in front of the future right-of-way line. Building setback to proposed family room and carport may not be verified for compliance until this information has been provided. Per LUC Sec. 3.2.6.5.B.1, the building setback required from Tucson Blvd is based on the greater of, 21 feet or the building height measured from the back of future curb. 6. A note must be added to the site plan which states: "Vehicles may not back out into Tucson Blvd." 7. Dimension the setback from the proposed carport to the Drachman Street property line. Per LUC Sec. 3.2.6.5.A, the minimum building setback required from the front of the carport to the Drachman Street property line is based on the greater of 20 feet or 1 ½ times the carport height. 8. Provide a complete floor plan of the existing residence and the guest house to verify the number of bedrooms on-site. Bedroom. The term bedroom shall include all of the following. A. Any room that is designated as a bedroom. B. Any enclosed room which has a minimum area of sixty (60) square feet and has an accessible opening to the exterior of the building in compliance with the International Building Code (IBC), whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen, and bathrooms. C. Any room designated as a bedroom for the purpose of any other code requirement. 9. If this property contains two (2) single family dwellings, LUC Sec. 3.5.7.1.H states: For all lots containing two (2) or more single family dwellings, with the second dwelling having more than one bedroom, all parking and maneuvering must be located on-site, either in a side or rear perimeter yard. The vehicular use area must be improved, which includes surfacing, striping, and provisions of barriers in conformance with Development Standard 3-05.0. Vehicle parking spaces may not be located in a vehicular use area in any front street perimeter yard. Tandem parking or alley access is not allowed. (LUC Sec. 3.5.7.1.G) 10. Note the zoning classification (R-1) on the adjacent properties to the north and west of the subject site. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/07/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 03/07/2005 | SUE REEVES | REJECT SHELF | Completed |