Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM03998
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/20/2004 | Jim Egan | FIRE | REVIEW | Approved | |
| 09/20/2004 | Joseph Linville | LANDSCAPE | REVIEW | Denied | 1) Revise the landscape plan to clearly delineate the limits of disturbance. DS 2-07.2.2.B 2) The project includes impact to riparian habitat, The City of Tucson General Plan, Element 4: Community Character and Design, Policy 2 promotes a more sensitive response to washes, slopes, and natural habitat. It states "Protect and restore natural watercourses". The Interim Watercourse Improvement Policy provides that protection and preservation of natural drainage systems should be the primary emphasis of City stormwater management efforts. Nonstructural solutions to flooding hazards shall be the preferred strategy over structural solutions. Revise the plans as recommended in the Drainage and Slope Assessment prepared by Project Engineer Larry K. Roberts, P.E. of Tetratech or as necessary. 3) Provide barriers at the perimeter of the driveway/vehicular use area to prevent vehicular access to unpaved portions of the site or adjacent parcels. DS 3-05.2.3.C.1 4) This project overlaps with a planned Department of Transportation project (L-2004-002) to revegetate portions of the site and the adjacent La Cholla Boulevard right-of-way. Contact Gary Wittwer of DOT to resolve potential coordination issues. Add notes to the plans if necessary. 5) The site is subject to a the provisions of the Hillside Development Zone. Approval of a HDZ application is required prior to site plan approval. Revise the plan as necessary to comply with applicable HDZ criteria and take necessary steps to comply with DSD Full Notice Procedure, TCC, Sec. 23A-50 and 23A-51. |
| 09/24/2004 | JOE LINVILLE | NPPO | REVIEW | Denied | 1) The copy of the plant preservation plan received contains an aerial photo that is difficult to read. Submit a copy in which the plant locations can be distinguished from the background. DS 2-15.0 2) Revise the native plant preservation plan to include limits of grading/disturbance. Ensure that the plant inventory encompasses all protected plants within these limits. Disturbance limits are to include all areas of the site where development may impact protected plants. DS 2-15.0 |
| 09/28/2004 | DAN CASTRO | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: David Rivera Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: T04CM03998 Booster Station- Utilities Distribution 2118 W. Anklam Road Site Plan Transmittal date: 1st Review October 1, 2004 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The proposed use is "Booster Station" is classified as Distribution System and falls under the Utilities Use Group. The proposed use is not permitted as a principal in the RX-2 zone unless processed and approval is granted through a Special Exception process. The proposed use is subject to specific performance criteria and approval through a Zoning Examiner Full Notice Procedure. In addition the site must meet the development requirements for the applicable development designator "13". Special Exception Land Uses. The following Land Use Classes are not permitted within this zone, unless approved through the special approval procedure noted for the Land Use Class, and are subject to any additional conditions listed. The number or letter in quotation marks following the Land Use Class refers to the Development Designator provisions of Sec. 3.2.3. For further information concerning Special Exception Land Use applicability, refer to Sec. 5.3.9. (Ord. No. 8653, §1, 2/26/96) RX-2 zone Special Exception Land Use: C. Utilities Use Group, Sec. 6.3.12 1. Distribution System "13", subject to: Sec. 3.5.11.1.A, .B, .E, .H, .I, and .K and approval through a Zoning Examiner Full Notice Procedure, Sec. 23A-50 and 23A-53. (Ord. No. 9967, §2, 7/1/04) 3.5.11 UTILITIES USE GROUP. Performance Criteria 3.5.11.1 Distribution System. A. The setback of the facility, including walls or equipment, is twenty (20) feet from any adjacent residential zone. B. Where a facility is not enclosed within a building, the surrounding screen shall be used as the building wall for the purposes of setbacks in Sec. 3.2.3.2. E. The use may not have any service or storage yards. H. Any building housing such facility shall be in keeping with the character of the zone in which it is located. The Design Review Board (DRB) shall review all applications and make recommendations to the Zoning Examiner. The DRB reviews architectural style, building elevations, materials on exterior facades, color schemes, new mechanical equipment locations, lighting of outdoor areas, window locations and types, screening, landscaping, vehicular use areas, and other contributing design features. (Ord. No. 9967, §3, 7/1/04) I. The use must be located wholly within an enclosed building or within an area enclosed on all sides with a masonry wall or compact evergreen hedge, not less than six (6) feet, nor more than ten (10) feet, in height. K. Limited to water pumping and storage facilities, telephone exchanges, and power substations with an input voltage of no greater than one hundred thirty-eight (138) kilovolts. 2. Please clarify if the land on which the power booster is to be split from the Pima Community College District parcel. If so A lot split application and a separate fee is required. If the land is a lease agreement with a recorded legal description of the parcel the lease constitutes a lot split as stated in the land use code section 4.1.2. Please apply for a lot split application. The lot-split application must be completed prior to final approval of the site plan. Please call me if you have specific questions regarding this requirement. Label the distance and bearings of the proposed lot or lease area. DS 20-02.2.1.A.2 and .5 3. Label the setback distance of the building from the La Cholla property line and the interior property lines. Label the setback distance from all property lines to all proposed equipment. The minimum building setback from adjacent residential zoning is 20 feet for facility including walls and equipment. DS 2-02.2.1.A.7 and LUC performance criteria 3.5.11.1.A 4. A minimum of two vehicle parking spaces is required for this use. One of the spaces must be handicapped accessible with and eight access aisle. The vehicular parking area does not have to be paved but must provide for dust control with compacted gravel. Please show on the plan that two vehicle-parking spaces are provided and revise the parking calculation to state that a minimum of two spaces is required and that two spaces are provided. Each space must be 8.5 feet in width by 18' feet in length. Revise the plan as required. DS 2-02.2.1.A.8 5. Draw and label existing and future sight visibility triangles. DS 2-02.2.1.A.10 6. PAAL areas for two-way traffic must be 24 feet in width. The proposed PAAL/driveway area does not meet the minimum width. The PAAL must also be paved with a minimum of double shot chip seal. Please revise as required. DS 2-02.2.1.A.11 7. A four-foot wide concrete sidewalk is required from the La Cholla Boulevard property line to the building. This sidewalk must be raised concrete or must be physically separated from the PAAL. The sidewalk must also connect to the handicapped accessible parking space access aisle. The required four-foot wide sidewalk and the required 24-foot wide PAAL must be provided within the proposed driveway area from La Cholla Blvd. To the site area. The proposed driveway will not accommodate the required elements and therefore the width the driveway must be increased to a minimum of 28 feet. The legal description for the lot split or lease area must be revised. Additional comments may be forthcoming on this item. DS 2-02.2.1.A.12 8. If applicable indicate the location of existing or proposed freestanding signs including billboards. The location, size and type of sign must be labeled. DS 2-02.2.1.A.13 9. Future curb and sidewalk must be drawn on the site plan. Both the curb and sidewalk must be labeled and dimensioned from centerline. DS 2-02.2.1.A.19 10. If applicable draw and label all existing easements located on the site in addition to the proposed easements. The location, purpose, width and recordation information must be labeled. 11. If applicable proposed freestanding lighting for this facility must be drawn and labeled on the site plan. The location, type, and height of light poles must be labeled. DS 2-02.21..A.25 12. See Landscape review comments related to landscape borders, screening, and NPPO requirements. In addition this site is subject to the regulations of the Hillside Development Zone. A separate application and submittal packet must be included with the next site plan submittal. The hillside review will occur concurrently. Please see LUC section 2.8.1 for more information related to the hillside development and the applicable criteria. DS 2-02.2.1.A.27 13. List the zoning of the property and label the adjacent zoning for the north, west and south properties. The zoning for the P.C.C.D. Parcel is RX-2 and the adjacent zoning will remain RX-2 after the split. DS 2-02.2.1.A.28 14. List the existing and proposed use. The proposed use is Distribution System "13", subject to: Sec. 3.5.11.1.A, .B, .E, .H, .I, and .K and approval through a Zoning Examiner Full Notice Procedure, Sec. 23A-50 and 23A-53. DS 2-02.2.1.A.31 15. Prior approvals, such as Development Review Board, Lot Development Option, Board of Adjustment, Historic District Advisory Board, and Historical Commission, Special Exceptions, etc. must be listed on the plan. DS 2-02.2.1.A.38 16. The following information related to the applicable development designator "13" for the proposed use must be listed on the plan. List the following items in a matrix or as notes: Site area required and actual site area (min. site area required = 16,000 sq. ft., actual is 9,500 sq. ft.), floor area ratio max allowed and actual, lot coverage max allowed and actual, max building height allowed and proposed, perimeter yard indicator "DD", and the number of parking spaces required and number provided. A Board of Adjustment variance will be required for the minimum lot area proposed. DS 2-02.2.2.A Also submit a separate response letter stating how all performance criteria requirements as listed in comment one (1) are to be met. 17. Additional comments may be forth coming, based on the re-submittal of the revised site plan and response comments. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and landscape plan and requested documents. |
| 10/02/2004 | DAVID RIVERA | HANDICAP-SITE | REVIEW | Denied | see zoning comments related to handicapped parking and sidewalks. |
| 10/13/2004 | Elizabeth Eberbach | ENGINEERING | REVIEW | Denied | ACTIVITY NUMBERS: T04BU02166, T04CM03998 LOCATION: T14S, R13E, Section 9 SUBJECT: Tucson Water Booster Grading Plan Engineering Review REVIEWER: Elizabeth Eberbach TO: Dan Denman, Tucson Water 310 West Alameda Tucson Arizona 85747 SUMMARY: DSD Engineering Division has reviewed the plan set submittal for Grading Plan review, and does not recommend approval until the following items are addressed. GRADING PLAN COMMENTS: 1) Admin.Dir.1.07-6.III.A: This project shall meet all applicable City Codes, Development Standards, and other City development requirements per this directive. 2) DS Sec.9-04.3.1.B.6: The temporary construction easement appears to be showing a potential for excessive disturbance of the hillside development area, regulatory floodplain, and riparian area, and does not match the Landscape Plan. Address the following: a) Clarify extents of disturbance area needed to construct project fill pad and erosion protection structures. It is expected that the construction of the erosion protection structures not be built from the wash side; provide construction profile detail showing grading limits at erosion protection structure minimizing disturbance of wash. b) Revegetation and other permanent sediment and erosion control measures need to be called out for proposed disturbance areas at boundaries of grading limits. c) A heavy-duty construction fence will be required at the grading boundary in the wash area and within the floodplain. 3) DS Sec.11-01.4.1.C.3: On the grading plan, show and label delineation for disturbance area and show limits of grading. Provide dimensioning for clarification. 4) DS Sec.11-01.4.1.C.3: Address the following grading comments for sheet 2: a) Revise extents of erosion protection structure so that the Tucson Water site will be protected from 100- year floodplain scour and erosion. b) Provide estimates for total disturbance area in square feet on grading plan. c) Clarify drainage runoff at northeast corner of project; there appears to be ponding. Provide sufficient grading area to provide necessary grading to prevent ponding. Shoe flow arrows to indicate proposed direction of flow at the northeast corner of the site. d) Label and provide local benchmark with location on plan view, and provide datum. e) On planview, clarify locations of pavement and gravel areas as specified in General Note 3. f) Provide clarification with minimum finished grade elevations showing that all structures including hydro-tank foundation is one foot above the regulatory floodplain water surface elevation. g) Show on planview locations of stabilization practices, and describe or provide details for interim erosion control methods. 5) DS Sec.11-01.4.1.C: Add the following general grading notes: a) Revise General Note 1 to clarify that all grading is to remain within grading limits as shown. b) All grading shall conform to Development Standards Sections 11-01 and 9-04 and the current IBC. c) A Right-of-way Use Permit may be required for any earthwork construction within the existing public right-of-way. d) Add notation or general grading note stating that the location for construction access to site shall be from the proposed driveway only. e) Any future walls that may need to be constructed require separate building permits. f) Call 791-5550 for Final Grading inspection. g) Specify that erosion and sediment controls shall be designed to retain sediment on site to the extent practicable. h) Specify that when sediment escapes the construction site, offsite accumulations of sediment must be routinely removed and at a frequency sufficient to ensure no adverse effects on water quality. 6) DS Sec.10-02.2.2.5.D: With resubmittal, submit a floodplain use permit application for any general grading for the project where fill and disturbance is proposed in the floodplain. The floodplain use permit will be issued concurrently with the grading permit once it is approved. 7) DS Sec.10-02.2.3: Provide updated drainage report addressing the following: a) Explain why this site was chosen while the Drainage and Slope Assessment letter dated August 3, 2003 recommends another site. b) Provide scour calculations for basis of design for erosion protection structure. c) Provide the encroachment analysis showing assumptions, calculations, and discussion of results. d) Clarify extents of erosion protection; discuss scour potential at ends of erosion protection structure that does not fully extend to 100-year floodplain limits. Show protection for Tucson Water site so that their site will be protected from floodplain scour and erosion. e) Provide WSEL at locations upstream and at erosion protection structure adjacent to the project. Establish minimum finished grade elevations for hydro-tank foundation and other equipment pads. 8) DS Sec.11-01.2.3.B: A grading bond shall be posted for native seeding at (or before) issuance of grading permit. The amount of this bond will be determined upon submittal of square footage of disturbance. 9) DS Sec.10-02.14.2.6: Provide a copy of the soils report discussing soil conditions in the wash where the project is located, and potential for hydro-collapsing soils with any recommendations for setbacks from the utility structures. Address all the above comments. For resubmittal, provide 3 copies of the revised grading plan, a floodplain use permit application, a revised bound drainage report, and if necessary, a revised landscape plan sheet. If you have any questions, call me at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/14/2004 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 10/14/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |