Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T04CM03978
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/01/2004 | Jim Egan | FIRE | REVIEW | Approved | |
09/15/2004 | DAVID RIVERA | ZONING | REVIEW | Passed | |
09/16/2004 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
09/16/2004 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The applicable code for all commercial plumbing projects is the 1994 Uniform Plumbing Code with State of Arizona Amendments. 2. Show how the potable water piping for the treatment has been sized. Include all fixtures and the potable water requirements of the process equipment when calculating the total demand and determining pipe sizes. Reference Sections 610.1 and 610.5, UPC 1994. Note: Limit the water velocity to less than 8 fps for the CPVC piping and size the pipe per IAPMO IS 20-93. Reference Section A 6.1, UPC 1994; IAPMO IS 20-93, Section 610.0; and IAPMO IS 8-92, Section 610.1. 3. Clarify the cross-connection control to be used for the three hose stations in the treatment facility and the external lube system for the SVE air blower. Potable water outlets with hose connections are required to comply with Section 603.3.6, UPC 1994 with AZ State amendments. 4. Provide freeze protection for 2"CPVC-3000, ¾"CPVC-3004, ¾"CPVC-3006, and ¾'CPVC-3000. Reference Section 313.6, UPC 1994. |
09/16/2004 | ROBERT SHERRY | WATER | REVIEW | Approved | |
09/17/2004 | Linda Buczynski | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
10/01/2004 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | T04CM03976 .. 475 E ELVADO ROAD .. CONTROL BUILDING #2 .. .. T04CM03977 .. 900 E SUSANA STREET .. CONTROL BUILDING #1.. .. T04CM03978 .. 900 E SUSANA STREET .. WALL AND ENCLOSURE .. .. T04CM03979 .. 900 E SUSANA STREET .. CONTROL BUILDING #3 .. .. DGL .. .. BUILDING COMMENTS - 1st REVIEW S1. Stepped foundations drawing CS-12, revise bottom of footings to comply with IBC Sec 1805.1, slope may not exceed 1:10 vs 1:2 on stepped footing details. S2. Provide locations for buildings and structures by dimension from two adjacent property lines for each building or structure permitted. S3. Provide structural calculations for footings and foundations , including stemwalls and address pipe and cable support design , attachment to and loads on masonry walls. S4. Provide Inspection Program for Special Inspections required by Uniform Administrative Code Section #306, as amended . S5. Special Inspection required for : 1. Masonry 2. Foundation excavation 3. Concrete 4. Field welding 5. Backfill S6. Provide shop drawings for : 1. Precast concrete roof panels 2. Grating S7. Detail connection of blocking to precast , ref details side bearing , edge flashing , end bearing option 1 and end bearing option 2, on drawing #CS-04. S8. Field bending of reinforcing in masonry is not acceptable , please provide corner bars as dowels where required , ref side bearing and end bearing on drawing #CS-04. S9. Provide complete structural calculations for buildings including lateral analysis and connection details. S10. Provide toilet , ramps and level landings at mandoors , revise plans and show accessibile route per IBC and ANSI A117.1-1998 ed. S11. Provide complete structural design including calculations and drawings for equipment platforms. S12. Provide complete structural design including calculations and drawings for above ground tanks over 5000 gallons. S13. Provide complete architectural and structural design including calculations and drawings for control building #2 and control building#3. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111 |
10/05/2004 | Gerry Koziol | WWM | REVIEW | Passed | |
10/05/2004 | LOREN MAKUS | ENGINEERING | REVIEW | Passed |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
12/07/2004 | LISA LESNY | OUT TO CUSTOMER | Completed |
12/07/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |