Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T04CM03919
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/27/2004 | Gerry Koziol | WWM | REVIEW | Approved | |
| 08/27/2004 | Andrew Connor | NPPO | REVIEW | Passed | |
| 09/19/2004 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 09/23/2004 | Terry Stevens | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T04CM03919 9/23/04 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. INDICATE THE LOCATION OF THE GAS LINE ON THE PROPERTY, AND WHERE IT ENTERS THE BUILDING. [ELECTRICAL PLAN INDICATES EXISTING GAS METER] FLOOR PLANS: 1. PLAN INDICATES REMOVING WALL IN EXISTING HOUSE BETWEEN BEDROOM AND LIVING ROOM. PROVIDE ROOF FRAMING DETAILS FOR SUPPORT OF ROOF. THIS WALL APPEARS TO BE A BEARING WALL. . STRUCTURAL PLANS: 1. DETAIL 1/A-02 INDICATES 8X8 POST WITH APPROPRIATE CAPS AND BASE CONNECTIONS. ROOF FRAMING PLANS HAVE BEEN CHANGED TO A 4X4 POST.---------CLARIFY 2. ROOF FRAMING PLANS INDICATE 2X8 RAFTERS------CROSS SECTION B-B INDICATE 2X10 ------CLARIFY THROUGH OUT ENTIRE PLAN. 3. ROOF FRAMING PLAN INDICATES A 33/4" GLULAM BEAM, THIS IS NOT A MFG. SIZE.-------CLARIFY MECHANICAL PLANS: 1. INDICATE REQUIRED HEAT STRIP FOR HEAT PUMP. MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS @ 791-5550 EXT. 1112 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/24/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 09/24/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |