Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T04CM03890
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/04/2004 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. (CODE SECTION/ DEVELOPMENT STANDARD) 1. Per LUC Sec. 3.2.6.5.B.1, a minimum building setback of 21'6" is required from the back of future curb location along Wetmore Road. The proposed site plan indicates the existing and proposed building addition is 21' 6'' in height. .(D.S. 2-02.2.1.A.19) (D.S. 2-02.2.1.A.21) 2. If a variance is approved, please note the case number, date of approval, variance/s granted, and conditions imposed as a general note on the site plan. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 |
| 11/08/2004 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal. 2. Indicate location of downspouts. D.S. 2-02.2.1.A.6 Add note, "All roof spouts will be routed under any adjacent sidewalk." Sidewalks shall be flood free for all storm discharges of up to a ten (10) year flood event. D.S. 2-08.3.1 & 4.1.E 3. Indicate and label existing and future sight visibility triangles. Near side 345', Far side 125'. Correct and revise. D.S. 2-02.2.1.A.10 4. Indicate drainage patterns, proposed finish floor elevation(s) and finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16 5. Wetmore Road is a MS&R with Future R.O.W. of 120 feet which intersects with Oracle Road requiring a widening of 150 feet. Correct and revise. Closed unused driveways/curb cuts. D.S. 2-02.2.1.A.18 6. Dimension and label all existing and future right-of-way. D.S. 2-02.2.1.A.19 7. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines along Wetmore. D.S. 2-02.2.1.A.21 8. There is no Note 8. The proposed expansion is within a retention basin. A drainage and a soils report are required. Indicate relocation of retention basin to meet City of Tucson drainage requirements under the Standards Manual for Drainage Design and Floodplain Management for this site. |
| 11/12/2004 | Andrew Connor | LANDSCAPE | REVIEW | Denied | 1) Screening from Wetmore Road per LUC Table 3.7.2-I is required for the the parking and loading areas. Revise the plans to identify the required screening elements. 2) On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way per LUC 3.7.2.4 as determined by Sec. 2.8.3.4. Revise the plans to locate the required 10' buffer along the entire street frontage, based on the MS&R right-of-way line. City Engineer approval is required locate up to five feet of the required border within the MS&R right-of-way. LUC 3.7.2.4.A.3 Provide verification, in writing, of any approvals from the City Engineer and documentation of any variances granted from provisions of the LUC. 3) Parking spaces or structures cannot be located with the sight visibility triangles along Wetmore Road. Per DS 3-05, Lines of sight will not be obscured between thirty (30) inches and six (6) feet through a triangular area adjacent to a driveway, a PAAL, an alley, or a street, where such access ways intersect with another street in a Tconfiguration. |
| 11/12/2004 | JOE LINVILLE | NPPO | REVIEW | Approved | Exception. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/02/2005 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 02/02/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |