Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE ONLY
Permit Number - T04CM03844
Review Name: COMMERCIAL-BLDG/FIRE ONLY
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/02/2004 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 09/14/2004 | Raul Palma | BUILDING-COMMERCIAL | REVIEW | Denied | City of Tucson, Development Services BUILDING AND STRUCTURAL COMMENTS 1) Provide complete masonry wall calculations. |
| 09/20/2004 | Peter McLaughlin | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Richard Giacetti 1636 N. Swan Rd #201 Tucson, AZ 85712 520-327-6600 FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: T04CM03844 Wells Fargo Bank addition 2825 N. Campbell Ave. TRANSMITTAL: September 21, 2004 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Provide a copy of the last approved site plan. DS 2-02.2.1.A.38 2. Provide a percent expansion calculation on the plan stating specifically the expansion percentage proposed. As expansions are cumulative include any previous expansions in the calculations (see comment 5). DS 2-02.2.2.A.6 3. It appears that the dimensions of the parking spaces adjacent and to the west of the proposed building addition may be less than the minimum required 18'´ 8- ½'. Dimension these spaces and the adjacent sidewalk in a detail on the site plan. The minimum width of a sidewalk may not be reduced to less than 4 feet by any obstruction such as the overhang of a parked vehicle. Show in the parking space detail showing how these spaces will meet code and indicating if wheelstop curbs are to be put in place to prevent parked vehicles from obstructing the sidewalk in the area of the proposed addition. If wheelstop curbs are to be used they must be dimensioned at 2-½ feet from the front of the parking spaces. DS 2-02.2.1.A.8 DS 3-05.2.3.C 4. Add the address of the site to the site plan sheet A 1.1. DS 2-02.2.1.A.2 5. The location map does not accurately depict the location of the project. Revise to indicate that the project site is much closer to Glenn St. than it is to Ft. Lowell Rd. Show the correct configuration of the parcel in the location map by indicating the vehicle access connection to Glenn St. DS 2-02.2.1.A.4 6. Although it is unclear, based on the site plan notes it appears that there was a previous expansion in 1986 of 186.6 square feet, and that the expansion proposed for this year is for 194.22 square feet. If this is the case, provide the approved site plan showing approval for the previous expansion, and revise the FAR calculations to include the new square footage of addition (4,618 sq. ft. + 194 sq. ft. = 4,812 sq. ft.). If there was an addition in 1986, revise the notes to indicate that this was a previous addition rather than a "new addition". ANS/IBC If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/23/2004 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 09/23/2004 | SUE REEVES | REJECT SHELF | Completed |