Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T04CM03697
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/23/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Arquitecto E. J. Ornelas 100 N. Stone Ave. Tucson, AZ 85701 FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: T04CM03697 Riverside Apartments 4-plex 1001 W. Speedway Blvd. TRANSMITTAL: January 23, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Add the existing use of the site to the notes. DS 2-02.2.1.A.32 2. Specify the maximum building height above design grade elevation along each building wall on the site plan. The heights shown on the elevation drawings are from finished floor elevation. Revise to also show height above design grade. An LDO will be required for the west and south lot line building setbacks. The required perimeter yard building setback is the greater of 10 feet and ¾ height of the highest point of the exterior structure wall per LUC 3.2.6.3. It appears that the highest point of the exterior structure wall along the west side of the building is over 28 feet, which requires at least a 21- foot building setback. The setback provided to the west lot line is only 13 feet, 6 inches. It appears that the highest point of the exterior structure wall along the south side of the building is about 26 feet, which requires approximately a 19-foot, six inch building setback. The setback provided to the south lot line is only 13 feet, 6 inches. Revise the site plan or submit an LDO application. DS 2-02.2.1.A.6 LUC 3.2.6.4 3. Revise keynote 9. A 6-inch vertical curb (not a wedge curb) is required at backup spur to prevent vehicles from backing over sidewalk. DS 3-05.2.2.D If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 01/26/2005 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | SUBJECT: Site Review - 1001 W. Speedway Bl. REVIEWER: Doug Williams DATE: 26 January 2005 ACTIVITY NUMBERS: T04CM03697 SUMMARY: Engineering Division has reviewed the Subject Drainage Statement and Site Plan. Approval of the site plan is not recommended at this time. Listed below are previous comments, or portions thereof, that have not been fully addressed which must be provided prior to Engineering Division approval: 1. Depict proposed finish grades (water harvesting and parking areas, building pad elevation, etc.) (DS 2-02.2.1 A16). 2. Provide estimated cut/fill quantities (DS 2-02.2.1 A17). 3. Provide an elevation for the project Bench Mark referenced (DS 2-02.2.1 A 23). 4. The last portion of previous comment # 9, "...or provide written approval from Environmental Services Department for the proposed pickup and storage locations", has not been fully addressed. The August 23, 2004 letter provided from John E. Clark, P.E., RLS, states that storage spaces for recycling containers should be shown on the plan, and as such, are requested to be depicted on a revised site plan (DS 2-02.2.1 A32 & DS 6-01.0). * A right of way permit will be required for all work in the public right of way. Contact Permits and Codes - Tucson Department of Transportation (TDOT) at 791-5100 for questions. If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us. Doug Williams Sr. Engineering Associate Engineering Division Development Services Department |
| 02/01/2005 | Joseph Linville | LANDSCAPE | REVIEW | Denied | Comments have not been addressed from previous submittal: 1. Indicate on landscape plan both the proper and common name of existing vegetation to remain in place per DS 2-07.2.2.A.1.d 2. All plants designated to be preserved-in-place shall be retained at their existing grade during and after construction. Preservation fencing per DS 2-06. Figure 1 is required to be installed beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. DS 2-15.6.A. Revise or remove Keynote #3 existing tree appears to be located in a sidewalk area, the tree cannot be counted as preserved in place if disturbed within the drip line. 3. Provide a 30"continuous screen along Riverside Dr. per LUC Table 3.7.2-1 4. Provide a 5' wall to screen the vehicle use areas from adjacent residential properties LUC Table 3.7.2-1 5. Provide one additional tree within the northeast street landscape border along Riverside Dr. per LUC 3.7.2.4 6. Landscape plan shall include irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. Show on the landscape plans the location of the irrigation system. |
| 02/01/2005 | Joseph Linville | LANDSCAPE | REVIEW | Denied | 1. Indicate on landscape plan both the proper and common name of existing vegetation to remain in place per DS 2-07.2.2.A.1.d. The correct species of existing Mesquite is Prosopis velutina revise as necessary. 2. Provide curbing for 30" screen wall and a minimum distance of two (2) feet must be maintained between and any wall, screen, or other obstruction per DS 3-05.2.2.3.B |
| 02/02/2005 | ANDREW CONNOR | NPPO | REVIEW | Approved | Comments have not been addressed from previous submittal: All plants designated to be preserved-in-place shall be retained at their existing grade during and after construction. Preservation fencing per DS 2-06. Figure 1 is required to be installed beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. DS 2-15.6.A. If trees can not be maintained at existing grades then an NPP plan must be submitted per DS 2-15.0 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/14/2005 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 02/06/2005 | SUE REEVES | REJECT SHELF | Completed |