Permit Number: T04CM03697
Parcel: 116171580

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T04CM03697
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/07/2004 Peter McLaughlin ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Arquitecto E. J. Ornelas
100 N. Stone Ave.
Tucson, AZ 85701
FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
T04CM03697
Riverside Apartments 4-plex
1001 W. Speedway Blvd.

TRANSMITTAL: December 8, 2004

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Add the existing use of the site to the notes.
DS 2-02.2.1.A.32

2. Specify the maximum building height above design grade elevation along each building wall. DS 2-02.2.1.A.6

3. No building elevation drawings or floor plans were included with this site plan submittal. For clarity regarding building height (see comment 2) please submit four-sided elevation drawings with maximum heights dimensioned along each side of the building, along with any other details which may be helpful in the site plan review. LUC 3.2.6.3
DS 2-02.2.1.A.6

4. Revise keynote 9 as a 6" vertical barrier is required at backup spur to prevent vehicles from backing over sidewalk. DS 3-05.2.2.D

5. Remove the reference to 5-foot aisle width for handicap car in the h/c parking detail as the single space required will requite an 8-foot aisle width for van accessible parking. ANS

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
12/07/2004 ANDREW CONNOR NPPO REVIEW Denied Comments have not been addressed from previous submittal:

All plants designated to be preserved-in-place shall be retained at their existing grade during and after construction. Preservation fencing per DS 2-06. Figure 1 is required to be installed beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. DS 2-15.6.A. If trees can not be maintained at existing grades then an NPP plan must be submitted per DS 2-15.0
12/07/2004 Andrew Connor LANDSCAPE REVIEW Denied Comments have not been addressed from previous submittal:

1. Indicate on landscape plan both the proper and common name of existing vegetation to remain in place per DS 2-07.2.2.A.1.d

2. All plants designated to be preserved-in-place shall be retained at their existing grade during and after construction. Preservation fencing per DS 2-06. Figure 1 is required to be installed beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. DS 2-15.6.A. Revise or remove Keynote #3 existing tree appears to be located in a sidewalk area, the tree cannot be counted as preserved in place if disturbed within the drip line.

3. Provide a 30"continuous screen along Riverside Dr. per LUC Table 3.7.2-1

4. Provide a 5' wall to screen the vehicle use areas from adjacent residential properties LUC Table 3.7.2-1

5. Provide one additional tree within the northeast street landscape border along Riverside Dr. per LUC 3.7.2.4

6. Landscape plan shall include irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. Show on the landscape plans the location of the irrigation system.
12/27/2004 Doug Williams ENGINEERING REVIEW Denied Previous comments have not been addressed. No drainage submittal could be found in the current submittal. See September review comments under "Engineering" folder.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/27/2004 TAMI ACHONG OUT TO CUSTOMER Completed
12/27/2004 ANGIE SHOFFSTALL REJECT SHELF Completed