Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM03697
Parcel: 116171580

Review Status: Completed

Review Details: SITE

Permit Number - T04CM03697
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/12/2004 Jim Egan FIRE REVIEW Approved
08/16/2004 ANDREW CONNOR NPPO REVIEW Denied All plants designated to be preserved-in-place shall be retained at their existing grade during and after construction. Preservation fencing per DS 2-06. Figure 1 is required to be installed beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. DS 2-15.6.A. If trees can not be maintained at existing grades then an NPP plan must be submitted per DS 2-15.0
08/16/2004 Andrew Connor LANDSCAPE REVIEW Denied 1. Indicate on landscape plan both the proper and common name of existing vegetation to remain in place per DS 2-07.2.2.A.1.d

2. All plants designated to be preserved-in-place shall be retained at their existing grade during and after construction. Preservation fencing per DS 2-06. Figure 1 is required to be installed beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. DS 2-15.6.A. Revise or remove Keynote #3 existing tree appears to be located in a sidewalk area, the tree cannot be counted as preserved in place if disturbed within the drip line.

3. Provide a 30"continuous screen along Riverside Dr. per LUC Table 3.7.2-1

4. Provide a 5' wall to screen the vehicle use areas from adjacent residential properties LUC Table 3.7.2-1

5. Provide one additional tree within the northeast street landscape border along Riverside Dr. per LUC 3.7.2.4

6. Landscape plan shall include irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. Show on the landscape plans the location of the irrigation system.
08/31/2004 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Denied See zoning review comments
08/31/2004 Peter McLaughlin ZONING REVIEW Denied TO: Arquitecto E. J. Ornelas
100 N. Stone Ave.
Tucson, AZ 85701

FROM: Peter McLaughlin Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
T04CM03697
Riverside Apartments 4-plex
1001 W. Speedway Blvd.

TRANSMITTAL: August 31, 2004

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This project is being reviewed for full code compliance.

2. Add the existing use of the site to the notes. DS 2-02.2.1.A.32

3. Specify the maximum building height above design grade elevation along each building wall. DS 2-02.2.1.A.6

4. Revise zoning setbacks in the zoning information table to specify that the MS&R setback is the greater of 21 feet or height of exterior structure wall dimensioned from back of future curb. Also, specify that the required side street perimeter yard setback is 10 feet along Riverside Drive. Remove the note on the drawing which reads "10-foot required street perimeter yard" along Speedway Blvd as this is incorrect. LUC 3.2.6.4
LUC 3.2.6.5
DS 2-02.2.1.A.7

5. The maximum residential density allowed in the R-2 zone, per development designator "K", is 15 units per acre. With a lot size of 11,043 square feet (0.25 acre) a maximum of three units is allowed. Revise plan to show three units or a board of adjustment variance approval will be required. If a variance is sought and approved, add the variance case number, the date of approval, and conditions imposed to the general notes on the plan. Provide a copy of variance approval letter prior to site plan approval. LUC 3.2.10
LUC 3.2.3.1.C

6. The pedestrian sidewalk located along the south lot line is labeled by keynote 6 as a 4-foot wide striped crosswalk. Crosswalks are only allowed where pedestrian circulation crosses a PAAL. Revise note to read 4-foot wide concrete sidewalk. Revise location of keynote 6 on the drawing to be more legible by locating it away from the canopy tree. DS 2-08

7. No building elevation drawings or floor plans were included with this site plan submittal. For clarity regarding building height (see comment 3) please submit four-sided elevation drawings with maximum heights dimensioned along each side of the building, along with any other details which may be helpful in the site plan review.
LUC 3.2.6.3
DS 2-02.2.1.A.6

8. Label and dimension any existing or proposed easements and add their recordation information to the site plan.
DS 2-02.2.1.A.20

9. The location, type, size and height of any proposed free-standing signage must be shown. Also, indicate if any billboards exist on the site.
DS 2-02.2.1.A.13

10. If free-standing outdoor lighting is proposed for this site, please detail on the site plan.
DS 2-02.2.1.A.25

11. Keynote 14 reads "3-foot backup spur" but the drawing dimensions a 6-foot backup spur. Revise to be consistent.

12. Label and dimensions existing and future curb and sidewalk along Speedway Blvd.
DS 2-02.2.1.A.19 & .21

13. Remove the reference to 5-foot aisle width for handicap car in the h/c parking detail as the single space required will requite an 8-foot aisle width for van accessible parking.
ANS

14. Dimension the width of the Parking Area Access Lane (PAAL) behind the northernmost parking spaces.
DS 2-02.2.1.A.11

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
09/07/2004 Doug Williams ENGINEERING REVIEW Denied SUBJECT: Site Review - 1001 W. Speedway Bl.
REVIEWER: Doug Williams
DATE: 7 September 2004
ACTIVITY NUMBERS: T04CM03697

SUMMARY: Engineering Division has reviewed the Subject Drainage Statement and Site Plan. Approvals are not recommended at this time. The following comments are offered:
DRAINAGE STATEMENT:
1. The effective FIRM panel (2226 K) indicates the Santa Cruz River 100-year storm is not contained within the existing channel banks. As such, a detailed engineering study providing acceptable calculations/recommendations for a minimum erosion hazard setback must be contained within a revised drainage submittal. A minimum setback of 490' from the top of existing bank to any proposed new structure will otherwise be required (Ref. Chapter 7 - Standards Manual for Drainage Design and Floodplain Management - DS 10-02.0 & Tucson Code, Section 26-7 Erosion Hazard - Building Setback Requirements).
2. Include minimum finished floor elevation, and erosion protection recommendations in a resubmittal.
SITE PLAN:
3. Provide lot dimensions and bearings (DS 2-02.2.1 A 5).
4. Depict and clearly label existing and future sight visibility triangles for a local street (Riverside Dr.) intersecting an Arterial Roadway (Speedway Bl) (DS 2-02.2.1 A 10 & 3-01.5.0).
5. Depict adjacent 100-year floodplain and adjacent water surface elevation for the Santa Cruz River (DS 2-02.2.1 A15).
6. Depict drainage patterns, proposed finished floor elevations and finish grades (DS 2-02.2.1 A16).
7. Provide estimated cut/fill quantities based on any drainage submittal revisions/recommendations (DS 2-02.2.1 A17).
8. Depict existing topographic contours at intervals not exceeding two feet, or preferably, spot elevations as pertinent, and Bench Mark based on City of Tucson Datum, including City Field Book and Page (DS 2-02.2.1 A 23).
9. The proposed refuse provision does not meet City of Tucson Development Standards for a centralized onsite refuse provision. Provide a revised site plan depicting an enclosure location with access/vehicle maneuverability thereto fully dimensioned and labeled, or provide written approval from Environmental Services Department for the proposed pickup and storage locations (DS 2-02.2.1 A32 & DS 6-01.0).
10. Depict and label roof drainage direction(s) and sidewalk scuppers at each downspout location for conveyance of 10-year flows, minimum under sidewalk areas (DS 2-08.4.1 E & 3-01.4.4 F).
11. The Site plan does not clearly indicate whether sidewalk is existing or proposed. If sidewalk exists, depict and label such, with dimensions noted. If not, depict and label new sidewalk to be constructed along both street frontages. New sidewalk is required as a part of new development of all properties, along the entire length of street frontages. Developments along MS&R streets shall install 6' sidewalks, 2' from back of curb, in accordance with Mayor and Council policy directive (DS 3-01.3.3 A).
* Please note that additional comments may be necessary upon resubmittal, depending upon the nature and extent of revisions that may occur to the plans.
* A right of way permit will be required for all work in the public right of way. Contact Permits and Codes - Tucson Department of Transportation (TDOT) at 791-5100 for questions.
If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Doug Williams
Sr. Engineering Associate
Engineering Division
Development Services Department

Final Status

Task End Date Reviewer's Name Type of Review Description
09/09/2004 DELMA ROBEY OUT TO CUSTOMER Completed
09/09/2004 DELMA ROBEY REJECT SHELF Completed