Permit Number: T04CM03672
Parcel: Unknown

Review Status: Completed

Review Details: SITE

Permit Number - T04CM03672
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/17/2004 JIM EGAN FIRE REVIEW Denied 1) Fire service line cannot be installed under structure.
2) Show proposed location of fire dept. connection.
08/17/2004 JOE LINVILLE NPPO REVIEW Approved
08/17/2004 JOE LINVILLE LANDSCAPE REVIEW Denied See comments of 8/10/04, attached.
08/26/2004 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal.

2. All lettering and dimensions shall be the equivalent of twelve (0.12") point or greater in size. The purpose of this requirement is to assure that all lettering is legible when reviewed and will maintain that legibility when reproduced and photographically reduced (microfilmed) for record-keeping purposes. D.S. 2-05.2.1.C Correct and revise all text on all sheets.

3. Indicate contour intervals. This should be placed together with the north arrow and scale. D.S. 2-02.2.1.A.1

4. Indicate legal property description. A Lot Combination is required. D.S. 2-02.2.1.A.2

5. Indicate lot dimensions and bearings. D.S. 2-02.2.1.A.5

6. Indicate all proposed buildings and structures, including roof slope and location of downspouts. D.S. 2-02.2.1.A.6 Add note, "All roof spouts will be routed under any adjacent sidewalk." Sidewalks shall be flood free for all storm discharges of up to a ten (10) year flood event. D.S. 2-08.3.1 & 4.1.E

7. Indicate all existing and future sight visibility triangles. D.S. 2-02.2.1.A.10

8. Clearly identified vehicular and pedestrian circulation. Show dimensions for all proposed driveways and PAALs. D.S. 2-02.2.1.A.12

9. Fully dimensioned loading space(s) and maneuvering area(s). D.S. 2-02.2.1.A.14

10. Indicate drainage patterns, proposed finish floor elevation(s) and finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16

11. Indicate estimated cut and fill quantities. D.S. 2-02.2.1.A.17 A grading review is required. Apply and submit grading application.

12. Indicate if street is Public or Private. Close unused curb cuts. D.S. 2-02.2.1.A.18

13. Dimension and label all existing and future right-of-way. D.S. 2-02.2.1.A.19

14. If applicable, indicate all easements of record to be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20

15. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. D.S. 2-02.2.1.A.21

16. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.A.23

17. New projects, including mobile home parks, consisting of 3 or more dwelling units will provide centralized on-site refuse storage, collection and pickup areas. Containers are to be placed so that the collection vehicle does not have to back into moving traffic, on or off the premises. D.S. 6-01.4.1.I Indicate refuse container location, size and access thereto fully dimensioned. Demonstrate vehicle maneuverability fully dimensioned. Indicate a dimensioned refuse enclosure detail as per D.S. 6-01.4.2 Contact John Clark of Environmental Services @ 791-3175 ext. 1136 to reach an agreement that does not meet Development Standards 6-01 and to obtain a DSMR.

18. Indicate building height and number of floors. Submit plans for proposed design of each floor.

19. Indicate property line on parcel and legend.

20. Identify square symbols along 6th Ave and Pennington St. Indicate symbol in legend.

21. Include a dimensioned cross section street detail of Pennington Street.

22. 6th Ave. is an arterial street and requires a minimum curb return for an arterial street to a PAAL of 25 feet. Correct and revise. TAMG 5.5

23. Minimum distance between curb cuts and driveways is 20 feet. Maximum curb cut width is 35 feet. Chapter 25-39

24. Refer to Transportation Access Management Guidelines for the City of Tucson 5.4 for driveway location on 6th Ave. Please contact Dale Kelch at 791-4001 ext.305 for assistance.
09/11/2004 Peter McLaughlin ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Michael Schmiit FROM: Peter McLaughlin
4545 E. McKinley Senior Planner
Phoenix, AZ 85008 Dev. Services Dept.
(602) 954-9060

FOR: Patricia Gehlen
Principal Planner
Development Services Dept.

PROJECT:
T04CM03672
Pennington Parking Garage
110 E. Pennington
Site Plan Review (1st review)

TRANSMITTAL: September 14, 2004

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

CODE SECTION/
DEVELOPMENT
STANDARD

1. Add the existing use of the site (i.e. vacant) to the project data.
DS 2-02.2.1.A.31

2. Clarify the proposed principal use on the plan. While the title block reads "parking garage", retail and office buildings are shown on the plan, and restaurants are listed in the site data.
DS 2-02.2.1.A.31

3. All lettering must be a minimum of 12 point (0.12"). Revise all lettering and dimensions which do not meet this minimum standard for microfilming/archiving.

4. Provide a parking detail showing fully dimensioned parking spaces and h/c parking spaces. Indicate the maximum slope of the van accessible handicap parking ramps and aisles to be provided on the typical detail. Show wheelstops where required per DS 3-05.2.3.C.1.
DS 2-02.2.1.A.8
ANS/IBC

5. Revise bicycle parking calcs to indicate that required bicycle parking is based on 8 percent of vehicle spaces provided. Add to the calculation the number of class 1 and class 2 spaces required and provided (refer to LUC 3.3.4).
LUC 3.3.3.5
DS 2-02.2.2.A.4
DS 2-02.2.1.A.9

6. In addition to the maximum allowed floor area ratio (FAR), provide a proposed FAR calculation to the plan.
DS 2-02.2.2.A.3

7. Dimension all building setbacks on the plan. The MS&R (6th Ave) setback is required to be the greater of 21 feet and height of exterior structure wall from back of future curb location. Remove the note which reads "setbacks N/A - see encroachment memos"
DS 2-02.2.1.A.7
LUC 3.2.6.5

8. One of every eight or every fraction of eight handicapped parking spaces must be van accessible per IBC Sec. 1106.4. The van accessible space must be served by an 8-foot wide access aisle. Revise plan and add the maximum slope of the handicapped aisle to be provided. ANSI/IBC

9. Provide the maximum height and dimensions of the proposed buildings on the site plan. DS 2-02.2.1.A.6

10. Loading spaces are required to be 12' by 35'. Revise dimensions stated on the plan.
LUC 3.4.5

11. Dimension the width of Parking Area Access Lanes (PAALs) and vehicle entrance drives on the site plan.
DS 2-02.2.1.A.11

12. Add the legal description to the plan. According to the Assessors Office this site is made up of 2 lots. These lots must be combined with an Assessors tax combo form and a recorded covenant which can be obtained from the zoning review counter. Please provide documentation of lot combination. Dimension property lines on the drawing.
DS 3-05.2.2.B.2
DS 2-02.2.1.A.6

13. Add the adjacent zoning to the site plan. DS 2-02.2.1.A.28

14. Add future and existing right-of-way dimensions to the plan. DS 2-02.2.1.A.19

15. Show continuous pedestrian circulation system fully dimensioned on the plan. DS 2-02.2.1.A.12
DS 2-08.4.1

16. If administrative waivers are being sought for the above requirements, or from any other requirements, please provide copy of letter documenting approval of waivers.



If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.


If you have any questions about this transmittal, please call (520) 791-5608.
09/14/2004 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Denied

Final Status

Task End Date Reviewer's Name Type of Review Description
09/14/2004 ANGIE SHOFFSTALL OUT TO CUSTOMER Completed