Permit Number: T04CM03424
Parcel: 123050420

Address:
2140 E EDISON ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T04CM03424
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/08/2004 Terry Stevens BUILDING-RESIDENTIAL REVIEW Denied 1. A Zoning issue still remains concerning the metal carport. Zoning has removed their approval. To comply:
- Callout carport on site plan
- Dimension to carport from the front and side property lines
- Provide height of structure.
Walk plans through zoning to gain approval prior to next submittal.

2. Provide calculations (or ICBO report) to justify structural integrity of metal carport. Include its attachement to the house in the calculations. Provide all pertinent details of the connection.

3. Construction of new foundation wall : Provide vertical #4 rebars at 48" o/c, bond beam at top of stem wall, H2.5 from top plate to joist. Also, Special Inspection is required for epoxy bolting. Consider elimanating epoxy bolt callout and simply providing blocking at the cantelivered joist ends.

4.Note that light fixtures in clothes closets shall be installed in accordance with E3903.11.

ANY QUESTIONS PLEASE CONTACT NEIL SAUNDERS @ 791-5550 x1113.