Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM03352
Parcel: 126211120

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM03352
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/20/2004 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T04CM03353

8/20/04 645 S. GOLONDRINA 2M

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.
2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

STRUCTURAL PLANS:

1. PROVIDE A BEAM UNDER THE CANTILEVERED PORCH ROOF, A FULCRUM, OR JUSTIFY THE EXISTING TRUSSES ABILITY TO CARRY THE ROOF LOAD.

ELEVATIONS:

1. SOUTH ELEVATION / A2.3 ; THE NOTE ABOVE THE PARAPET, RE: THE 48" CANTILEVER, CONFLICTS WITH THE 36" CANTILEVER MENTIONED ELSE WHERE. PLEASE CO-ORDINATE.

SECTIONS - DETAILS - MISC. NOTES:

1. SECTION A and DETAIL 1 / A2.3 ; HOW DOES THE GYP BOARD ON THE CEILING COMPLY WITH TABLE R702.3.5, FOOTNOTE D ?

PLUMBING PLANS:

1. PROVIDE THE SIZE OF THE WATER METER. IS IT'S SIZE ADEQUATE FOR THE HOUSE AND THE GUEST HOUSE ? SEE UPC TABLE 6-4 .

MECHANICAL PLANS:

1. THE "CASITA" MUST BE PROVIDED WITH HEATING CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF
68 DEGREES AT A POINT 3' ABOVE THE FLOOR PER R303.6. IS THE A/C A HEAT PUMP? HEAT STRIPS?

ELECTRICAL PLANS:

1. CIRCUIT 7, SUPPLYING THE BATH, IS REQUIRED TO SERVE ONLY THE BATH. THE TWO RECEPTACLES IN THE LIVING ROOM CAN'T BE ON 7. SEE R3603.4 .





MODEL ENERGY CODE:

1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11.

2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS
AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED.

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
08/20/2004 CINDY AGUILAR OUT TO CUSTOMER Completed
08/20/2004 ANGIE SHOFFSTALL REJECT SHELF Completed