Review Date Reviewer's Name Type of Review Description Status Comments
09/20/2004 Joseph Linville LANDSCAPE REVIEW Denied 1) The Speedway Boulevard right of way area adjacent to the street landscape border is required to be covered with
an appropriate inorganic ground cover, such as decomposed granite. Consult with the City Engineer regarding appropriate treatments in the public areas. Typically, no larger than 1/4"- decomposed granite is allowed in the required pedestrian zone. Revise the notes regarding decorative gravel in all areas. LUC 3.7.2.4.A.4
09/29/2004 DAN CASTRO HANDICAP-SITE REVIEW Approved
09/29/2004 Daniel Castro ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were
addressed. (CODE SECTION/ DEVELOPMENT STANDARD)

1. A total of 24 vehicle parking spaces are required. A total of 20 vehicle parking spaces are provided resulting in a deficiency of four (4) vehicle parking spaces. (LUC Sec. 3.3.4) (D.S. 2-02.2.1.A.8)

2. Since a Board of Adjustment variance will be applied for, please list on the site plan the case number, date of approval, variances granted, and conditions imposed. (D.S. 2-02.2.1.A.38)

3. Review of this plan by the Zoning Review Section may be done over the counter. Please contact Dan Castro to set an appointment.

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
10/11/2004 Paul Machado ENGINEERING REVIEW Denied To: Seaver Franks DATE: October 12, 2004
Architects
2552 N. Alvernon Way Tucson, Arizona 85712

SUBJECT: 9131 E Speedway Blvd, Dental office.
Site plan T04CM03269 (Second Review)
T14S, R15E, Section 03

RESUBMITTAL REQUIRED: Site Plan.

The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. The SVT's on the plans are not shown properly. The existing SVT should be depicted as starting from the face of curb or the existing edge of pavement, thence the beginning of the 20' leg of the SVT. The future SVT shall be depicted as starting from the future face of curb from the Major Streets and Routes (MS&R) Plan, which for a future R/W width of 200' is 12' from the R/W. Then the 20' leg would begin for the future SVT. When the correct SVT's are shown, to expedite the plans, I will review and approve the SP over the counter if so desired. Please feel free to call me if you have any questions on the placement of the SVT's. Per previous comment.

Drainage Statement:
1. The Drainage Statement is accepted.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/9131 E Speedway Blvd site 2

Final Status

Task End Date Reviewer's Name Type of Review Description
10/12/2004 BETH GRANT OUT TO CUSTOMER Completed
10/12/2004 ANGIE SHOFFSTALL REJECT SHELF Completed