Permit Number: T04CM03184
Parcel: 134244330

Address:
6307 E 22ND ST

Review Status: Completed

Review Details: SITE

Permit Number - T04CM03184
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/12/2004 Jim Egan FIRE REVIEW Approved
07/19/2004 ANDREW CONNOR NPPO REVIEW Approved
07/19/2004 Joseph Linville LANDSCAPE REVIEW Denied The site and grading plans indicate a screen wall. Show the location and size of proposed wall on landscape plan per DS 2-07.2.2.3.
07/29/2004 Paul Machado ENGINEERING REVIEW Denied To: Bruce Patton DATE: August 2, 2004
Rick Engineering Company, Inc.
1745 E. River Road, Suite 101
Tucson, Arizona 85718
SUBJECT: 6307 E. 22nd St. New Autozone
Grading Plan T04CM03184 (First Review)
T14S, R15E, Section 18

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement.

The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. The contour interval is called out under the North arrow on the Site Plan, yet there are no contours, please correct.
3. Please provide property description per D.S. 2-02.2.1.3.
4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. The far side SVT for the new D/W at the NE corner of the project should drawn at the face of curb. Please adjust.
5. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. Handicap ramps are required at new D/W at the NE corner of the property.
6. Complete activity number (T04CM03184) on all sheets per D.S. 2-02.2.1.29.
7. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. On sheet 2 the trash enclosure shows the bollards encroaching 1 foot into the 10' clear space required for the dumpster. Also a 40' clear space es required in front the trash enclosure for the vehicle approach. Perhaps skewing the enclosures may work. Please address.
8. A private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
9. Add note: "Depress all landscaped areas 6" maximum for water harvesting".

Drainage Statement:
1. The Drainage Statement has been accepted by Engineering.
2. Show the project address on the cover of the Drainage Statement.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/ 6307 E. 22nd St site
08/05/2004 Peter McLaughlin ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Rick Engineering
1745 E. River Road, Suite 101
Tucson, AZ 85718
(520) 795-1000

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner
Development Services Dept.

PROJECT:
T04CM03184
AutoZone Store
Wilmot Road & 22nd Street
6307 E. 22nd Street (1st review)

TRANSMITTAL: August 9, 2004

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1. This project is a new building and was reviewed for full code compliance.
DS 2-02

2. A minimum 4-foot sidewalk is required between the east side of the building and the four parallel parking spaces. Note: The width of the proposed parallel parking spaces may be reduced to as little as 8 feet.
DS 2-08.4.1.C
DS 2-02.2.1.A.12

3. The typical parallel parking space detail on sheet 1 of 5 labels the minimum width of adjacent one-way drive as 18.5 feet, but the drawing on sheet 2 of 5 shows it to be only 189 feet. Revise for consistency.

4. Wheelstop curbing is required in parking spaces where parked vehicles may overhang landscaped areas, walls, etc. Show the required wheelstop curbing in the vehicle spaces along the west side of the parking lot where vehicles may strike the 30" screen wall or the freestanding site lighting.
DS 3-05.2.3.C.1

5. Dimension the width of the access drives at the points of egress and ingress.
DS 2-02.2.1.A.11

6. Add the height and dimensions of existing/proposed signage. The existing sign located near the west entrance drive to the site is within the future sight visibility triangle. If it is over 30" in height above the at-grade centerline of the adjacent PAAL it must be removed or a DSMR application approval is required. If a DSMR is sought and approved, add the case number, date of approval and conditions on the site plan. DS 2-02.2.1.A.13
DS 3-01.5.1.A

7. Indicate the maximum slope of the van accessible handicap parking ramps and aisles to be provided on the typical detail.
ANSI/IBC

8. Provide a copy of recorded cross access agreement with property to the south of the site. Add recordation information for the access agreement to the site plan. DS 2-02.2.1.A.20

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
08/09/2004 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Denied See Zoning Comments

Final Status

Task End Date Reviewer's Name Type of Review Description
08/19/2004 LISA LESNY OUT TO CUSTOMER Completed
08/19/2004 SUE REEVES REJECT SHELF Completed