Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T04CM03133
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/22/2004 | Gerry Koziol | WWM | REVIEW | Denied | NEED 8TH FLOOR CREDIT EVALUATION |
11/26/2004 | Neil Saunders | BUILDING-RESIDENTIAL | REVIEW | Denied | Plan Check Comments - Project T04CM03133 Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. General Requirements 1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned. 2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes. 3. All plans shall comply with 2003 IRC (less plumbing plans). Revise all notes and references. Floor Plan 1. Show that each water closet is located in a clear space not less than 30" wide and has a clear space in front not less than 21" per figure R307.2. Structural Plan 1. Special Inspection is required for epoxy bolts (105/S-2). Submit form. 2. HUSC68 is not recognized. 3. Structure does not meet prescriptive method for braced wall design. East face of addition must meet braced wall design per R602.10. Or provide lateral analysis. Mechanical, Plumbing and Electrical plan 1. Note on plans: Mechanical shall comply with 2003 IRC chapters 13 - 24. 2. Note that bathtub and shower enclosures shall be finished per P2710 with ceramic tile, or a listed enclosure, to a height of 72" above the drain per R702.4 and R307.2. 3. Note on plans that shower and tub / shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type. 4. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code. 5. Note on plan that all electrical work shall comply with 2000 IRC chapters 33 - 42. If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/29/2004 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
11/29/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |