Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T04CM03119
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/27/2004 | Jim Egan | FIRE | REVIEW | Approved | |
07/27/2004 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Provide roof drainage calculations and plans. Provide overflow protection for the roof. Clarify the effect of the existing roof as a possible contributing area for rain collection for the new roof. Reference Appendix D, UPC 1994. |
07/27/2004 | ROBERT SHERRY | WATER | REVIEW | Approved | |
07/27/2004 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide energy code compliance calculations. Reference Section 101.2, International Energy Conservation Code 2000. |
07/28/2004 | GERRY KOZIOL | WWM | REVIEW | Passed | |
07/29/2004 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | APPROVED FUP T04OT01418 |
08/09/2004 | Christy Foreman | BUILDING-COMMERCIAL | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES STRUCTURAL REVIEW COMMENTS DATE: 8-11-04 ACTIVITY NUMBER: T04CM03119 PROJECT NAME: WELLNESS CENTER ADDITION TO B'NAI B'RITH COVENANT HOUSE PROJECT ADDRESS: 4414 E 2ND ST ARCHITECT / ENGINEER: JACQUES GERSTENFELD PROJECT REVIEWER: CHRISTY FOREMAN PHONE:791-5550 EXT 1108 EMAIL: CFOREMA1@CI.TUCSON.AZ.US TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CFOREMA1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS. 1. Submit a complete code analysis. Clarify occupancy I-1 or R-2. See table 503 for height and area allowable. Separated use or non-separated use? Clarify allowable areas based on existing areas that additional square footage can be added. 2. Justify / clarify occupancy load for room added. Table 1003.2.2.2 3. What is on the other side of the wall from the exercise room. Clarify that existing bldg. Still meets code section 1009. Clarify no emergency exits for sleeping rooms are being blocked off. 4. Need clarification that existing building does not require to use this room for egress. See code section 1004.2.3 - new double door has a cylinder lock on the exterior, which could prevent egress. 5. 1003.3 Clarify door hardware height. 6. Ramp - conform to section 1003.3.4.1 & 1003.3.4.9. 7. Sht. A-5 specify pre-fabricated truss on roof framing plan - see structural calculations. 8. Provide acoustical tile attachment detail. |
08/17/2004 | Linda Buczynski | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. Provide detailed instructions on plans for the new feeder connection to the load side of the existing breaker. Demonstrate that the listing of the original equipment will not be violated. 2. Provide load calculations on the plans, demonstrating that the service will not be overloaded. |
08/26/2004 | Peter McLaughlin | ZONING | REVIEW | Denied | Approved site plan required. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
08/27/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
08/27/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |