Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T04CM03114
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/13/2004 | MELISSA POULIN | WWM | REVIEW | Approved | |
| 08/10/2004 | David Witt | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T04CM03114 8/11/04 7406 E. CUENAVACA PL. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. 5 / A-7 ; PLEASE PROVIDE A LANDING OUTSIDE THE MANDOOR. SEE R312.1.2 . FLOOR PLANS: 1. PLEASE CONFIRM THE "19'-4" " DIMENSION LEFT OF THE COVERED PORCH. 2. PROVIDE THE LOCATIONS OF TEMPERED GLASS PER R308.4. 3. 2'-8" IS THE MINIMUM WIDTH OF AN ALTERNATE BRACED WALL PANEL. SEE R602.10.6 . JUSTIFY THE 2'-0" BWPs AROUND THE COVERED PORCH. 4. PLEASE SPECIFY THE SIZE OF THE ATTIC ACCESS. WILL IT HAVE 30" OF HEAD ROOM IN THIS CLOSET? SEE R807. 5. LOCATE AND IDENTIFY SHEAR WALL TYPES AND LOCATIONS. THEY'RE OVER 25' ON CENTER. SEE TABLE R602.10.3 FOR CATEGORY C. STRUCTURAL PLANS: 1. SPECIFY THE RAFTERS AND THE RIDGE FOR THE OVERFRAME. THE OVER FRAME BLOCKS SOME OF THE VENTILATION FOR THE BODY OF THE HOUSE, BUT THE ADDITION OF A 22X30 VENT, OR TWO, WILL NOT ONLY PROVIDE VENTILATION IT WILL ALSO PROVIDE ACCESS TO THESE AREAS. 2. PROVIDE MANUFACTURER'S CALCULATIONS AND DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS CALCULATIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS. ELEVATIONS: 1. PLEASE SPECIFY THE HEIGHT OF THE TOP PLATE. SECTIONS - DETAILS - MISC. NOTES: 1. DESIGN LOADS / A-1 ; THE ADOPTED WIND SPEED IS 90 MPH. 2. CODE TABULATIONS / A-1 ; PLEASE CONFIRM THE R-1 CLASSIFICATION. SEE IBC SECTION 310 . 3. PLEASE CONFIRM THE TYPE OF CONSTRUCTION. SEE IBC TABLE 601 . 4. 5 / A-2 ; PLEASE DESCRIBE THE PLATE MATERIAL. 5. 6 / A-2 ; FOOTINGS ARE REQUIRED TO BEAR NOT LESS THAN 12" INTO THE UNDISTURBED GROUND. SEE R403.1.4 . 6. 3 / A-3 ; THE KEYNOTES ALL CAME OUT AS "4" . 7. 4 / A-3 ; PLEASE ILLUSTRATE THE TRIMMER STUDS UNDER THE HEADER. 8. HOLD-DOWN SCHEDULE / A-4 ; THE PAHD42 ISN'T RATED AT 1800# ON THE END STUD ON AN OUTSIDE CORNER. DID YOU MEAN HPAHD22 ? 9. GENERAL MECHANICAL NOTES / M-1 ; THE CODE OF REFERENCE SHOULD BE THE 2000 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED. PLUMBING PLANS: 1. PLEASE CORRECT THE TYPO, "1/4" GAS FROM METER…….". 2. PLEASE CORRECT THE TYPO, "1/4" SOV IN YARD BOX". 3. GAS: PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE, BTU DEMAND OF EACH APPLIANCE, SIZE OF EACH BRANCH, TOTAL DEMAND & TOTAL DEVELOPED LENGTH FROM METER TO MOST REMOTE APPLIANCE ON THE SYSTEM PER UPC 1217.2 4. FIXTURE CONNECTION SCHEDULE / P-1 ; 4 HOSEBIBS @ 3fu EACH EQUALS 12fu TOTAL. BUT 15fu (IN BRACES) IS LISTED AND 12fu ARE USED TO TOTAL 35fu. WHY IS "(15)" LISTED? MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC AND THE CITY OF TUCSON AMENDMENTS. 2. DOES HEAT PUMP #2 HAVE A FURNACE? ARE YOU SURE YOU WANT FURNACES WITH THE HEAT PUMPS? 3. PROVIDE A VENTILATION FAN FOR THE LAUNDRY. SEE R303.3 . 4. PLEASE PROVIDE COMBUSTION AIR FOR THE DRYER / FURNACE. SIZE PER STATE PLUMBING CODE TABLE A FOOTNOTE 3. 5. IF THE HEATING OR AIR CONDITIONING EQUIPMENT IS LOCATED IN THE ATTIC, SHOW LOCATION OF ACCESS, CATWALK AND WORKING PLATFORM. SHOW PROVISIONS FOR AND ROUTE OF SECONDARY CONDENSATE DRAIN PER M1305.1.3. ELECTRICAL PLANS: 1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC, INSTEAD OF THE NEC. 2. A RECEPTACLE IS REQUIRED WITHIN 3' OF THE LAVATORY IN THE HALL BATH. SEE E3801.6 AND E3603.4 . . 3. A RECEPTACLE IS REQUIRED ON THE WEST WALL OF THE LIVING AREA, WITHIN 6' OF THE FRONT DOOR. SEE E3801.2.1 THRU E3801.2.3 . 4. PLEASE NOTE ON THE PLANS THE LIGHT FIXTURE OVER THE TUB IS REQUIRED TO BE LISTED AS APPROVED FOR USE IN WET AREAS. SEE E3903.8 . 5. THE READILY ACCESSIBLE RECEPTACLE IN THE GARAGE IS REQUIRED TO BE GFCI PROTECTED. SEE E3802.2 . 6. INDICATE THE LOCATION OF CONVENIENCE OUTLET AND LIGHT SWITCH FOR ATTIC HEATING AND AIR CONDITIONING EQUIPMENT PER E3801.11 AND E3803.4. 7. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. 8. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/18/2004 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 08/18/2004 | BETH GRANT | REJECT SHELF | Completed |