Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM03033
Parcel: 135083800

Address:
7412 E JUAREZ ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM03033
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/14/2004 GERRY KOZIOL WWM REVIEW Approved
08/09/2004 Neil Saunders BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - T04CM03033

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

General Requirements

1. All corrections and revisions shall be made on the original tracings and two new sets of prints shall be returned.
2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure all corrections have been made, are complete and have been coordinated on all-applicable details and notes.

Foundation Plan

1. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 PSF is being used per table R401.4.1.
2. Note post footing as '24" square' and '18" square'
3. Detail 2; Footing width is a minimum of 16".
4. Callout #4 reinforcing on each detail.
5. Provide landing at exterior garage door per R312.
6. Size post footing at front corner of garage.
7. Note concrete slab thickness.
8. Footing will be required along entire garage bearing wall. Existing slab (6'x14') must have a footing underneath it.
9. Callout type of post base on all detail. Suggest ABE46.

Structural Plan

1. Show locations of all post on roof framing plan.
2. Spans for (2) 2x8 beam at new porch are not shown. These beams are likely to be inadequate. Resize.
3. Callout rafter hanger types.
4. Detail how (2) 2x8 beam at front of garage will attach to existing house.
5. Vertical 2x4 wall between new storage and new laundry will require a footing if the wall is to be bearing.
6. Provide roof slopes on elevations or cross sections.
7. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply.
8. Callout types of connectors on post and beam details (post caps and T straps).
9. Detail A. Provide blocking between existing rafters below Glulam beam.

Plumbing and Electrical Plans

1. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code.
2. Provide two-way cleanout outside new storage unit.
3. Size vent and waste pipe. Designate waste pipe material.
4. Only copper pipe is allowed under slab per 1994 UPC sec609.3.2.
5. Provide vent for dryer.
6. Note on plan that all electrical work shall comply with 2000 IRC chapters 33 - 42.
7. Outside receptacles shall be GFCI protected. Make note of this on plan.
8. Provide a switched exterior light at exterior garage door.
9. Designate circuit numbers at each new light or receptacle. Designate which lights, switches and receptacles are existing.

If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/12/2004 LISA LESNY OUT TO CUSTOMER Completed
08/12/2004 LISA LESNY REJECT SHELF Completed