Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T04CM02918
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/19/2004 | Andrew Connor | NPPO | REVIEW | Denied | 1. This site is subject to CITY OF TUCSON LAND USE CODE ARTICLE III. DEVELOPMENT REGULATIONS DIVISION 8. NATIVE PLANT PRESERVATION 2. Submit NPPO plan per DS 2-15.3.0. If you have any questions please call the Landscape Field Representative directly at 791-5640 Ext. 1140. |
| 08/20/2004 | Gerry Koziol | WWM | REVIEW | Approved | Septic review not yet approved. |
| 08/23/2004 | Paul Machado | ENGINEERING | REVIEW | Denied | To: Harrington DAP, LLC. DATE: August 24, 2004 Architectual Designers and Planners 6752 N. Los Arboles Circle Tucson, Arizona 85704-4111 SUBJECT: 8640 and 8602 E. Tanque Verde Site plan T04CM02918 (First Review) T13S, R15E, Section 33 Floodplain use permit T04OT01645 (First Review) T13S, R15E, Section 33 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. All proposed fill to conform to Section 13 of the 2000 IBC - Address the 2'grade differential of proposed lot grades from the existing site grades. 3. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15. 4. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 5. Please provide adjacent property grades for review in accordance with in 2000 IBC section 13 concerning fills. 6. List the consulting engineer and the owner/developer on the plans with the pertinent information. 7. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Drainage Report: 1. The Drainage Report has been accepted by engineering. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office, (520) 879-8010 fax, C:/8640 E. Tanque Verde Road site |
| 09/10/2004 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Michael St.Paul FOR: Patricia Gehlen Planning Technician Principal Planner PROJECT: T04CM02918 8640 E Tanque Verde Rd Clark Residence TRANSMITTAL: September 8, 2004 DUE DATE: COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. All lot splits and subdivision within the City of Tucson must be reviewed and approved by Development Services for the City of Tucson. A subdivision plat is required for splitting parcels of land equal to or greater than two and one-half acres, and for splitting of a parcel into more than three portions within the past twenty years. The minimum lot size is 144,000 square feet in the SR zone. LUC Sec 4.1.2 LUC Sec 2.2.4.2.A.1 LUC Sec 3.2.3.1.A LUC Sec 3.2.6.4 2. Please provide dimensions on all elevations from design grade (ground level) to the top of the exterior wall of each elevation. Please list these dimensions on the site plan. In addition, overall building height is measured from design grade to the middle, between the eave and the ridge, of the highest gable of a pitched or hipped roof. Please provide the building height on the site plan. LUC Sec 3.2.6.3 LUC Sec 3.2.7.2 3. The detached garage exceeds the maximum approval height of twelve feet (12'-0") for a detached accessory structure. Please revise the plans. LUC Sec 3.2.5.3.B 4. Please identify the zoning (SRĀ®) for this lot and the adjacent lots on the site plan. Please see the plot plan instruction and model that has been included with these comments. |
| 09/14/2004 | Terry Stevens | BUILDING-RESIDENTIAL | REVIEW | Denied | POSSIBLE CHANGES DUE TO ZONING DENIAL------HAVE NOT STARTED REVIEW------SPOKE WITH OWNER |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/15/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 09/15/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |