Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T04CM02796
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/22/2004 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Revise detail 1/M2 to conform to the requirements of Section 506.3.8, IMC 2000. Provide an approved drain outlet at the bottom of the fan scroll leading to an approved grease reservoir. |
| 10/22/2004 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Appliances to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps may require reduced pressure principle backflow preventers. Please submit equipment sheets of the icemaker for determination. Reference Section 603.0, UPC 1994. 2. Revise the termination shown for the WH-1 vent to comply with the requirements of Section 517.3, UPC 1994. |
| 10/25/2004 | Linda Buczynski | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 11/08/2004 | Christy Foreman | BUILDING-COMMERCIAL | REVIEW | Approved | CITY OF TUCSON DEVELOPMENT SERVICES STRUCTURAL REVIEW COMMENTS DATE: 10/9/04 ACTIVITY NUMBER: T04CM02796 PROJECT NAME: NEW RESTAURANT / LOFT PROJECT ADDRESS: 427 E. LIMBERLOST ARCHITECT / ENGINEER: STEPHEN MOSS PROJECT REVIEWER: CHRISTY FOREMAN TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CFOREMA1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS. 1. Clarify location of bldg. On site plan and dimension distances from existing buildings and property lines. Information necessary for code analysis Table 602 and Table 704.8. - Per location of building table 602 type VA construction requires 1 hr. wall - east wall. Clarify / justify including roof overhang per section 704- 704.11. 2. Further clarification of exit stairwell see section 1005.3.6.5 exterior stairway protection. This stairwell meets exception (1) therefore stair separation from interior of bldg. @ R-3 is not required. Therefore walls of stairwell are not required to be a firewall. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/10/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 11/10/2004 | SUE REEVES | REJECT SHELF | Completed |