Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM02754
Parcel: 13502134M

Address:
6964 E 22ND ST

Review Status: Completed

Review Details: SITE

Permit Number - T04CM02754
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2004 Jim Egan FIRE REVIEW Approved
06/18/2004 Andrew Connor NPPO REVIEW Denied Indicate the location, size, proper and common name of existing vegetation per DS 2-07.2.2.d.
06/18/2004 Andrew Connor LANDSCAPE REVIEW Denied 1. Submit original approved landscape plan.

2. Indicate the location, size, proper and common name of existing vegetation per DS 2-07.2.2.d.

3. Trees that are located in areas of required landscaping will be a minimum fifteen (15) gallon container size per DS 2-06.3.5.C. Shrubs are not an acceptable replacement for trees revise plan as necessary.
07/01/2004 PAUL MACHADO ENGINEERING REVIEW Denied To: Philip C. Hawtin DATE: July 1, 2004
T-Mobile
8916 Cardiff Place
Stockton, Ca. 95210

SUBJECT: 6964 E. 22nd Street, T-Moblie retail store
Site plan T04CM02754 (First Review)
T14S, R15E, Section 19

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement.

The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. Please provide property description per D.S. 2-02.2.1.3.
3. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
4. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
5. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17.
6. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
7. Show Site plan number (T04CM02754) on all sheets per D.S. 2-02.2.1.29.
8. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.
9. List the consulting engineer and the owner/developer on the plans with the pertinent information.

Drainage Statement:
1. A Drainage Statement is required. A DS is a brief description of drainage conditions applicable for a site which is not affected be 100-year flows of 100 cfs, or more, and is neither subject to detention requirements nor impacted by flows from a significant watercourse per S.M.D.D.F.M., chap. II, 2.1.3.
2. The content and format of the DS should follow S.M.D.D.F.M., chap. II, 2.1.3.
3. Show the project address on the cover of the Drainage Statement.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/6964 E. 22nd St Site 1
07/02/2004 DAVID RIVERA HANDICAP-SITE REVIEW Approved
07/02/2004 David Rivera ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/14/2004 LISA LESNY OUT TO CUSTOMER Completed
07/14/2004 ANGIE SHOFFSTALL REJECT SHELF Completed