Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM02682
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/24/2004 | Jim Egan | FIRE | REVIEW | Approved | |
| 06/28/2004 | JOE LINVILLE | NPPO | REVIEW | Approved | EXCEPTION |
| 06/28/2004 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 07/13/2004 | DAN CASTRO | HANDICAP-SITE | REVIEW | Approved | |
| 07/13/2004 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. (CODE SECTION/ DEVELOPMENT STANDARD) 1. Per Pima County Assessors Records, the site is comprised of four (4) parcels which must be combined by providing a copy of the recorded City of Tucson Lot Combination Covenant and a copy of the approved Pima County Assessors Tax Combination form. You may obtain a copy of the covenant online at: http://www.ci.tucson.az.us/dsd/Lot_Combo_Declaration.pdf or you may contact me at the number below. The Pima County Assessors Tax Combination Form may be obtained at the Assessors office. (D.S. 2-02.2.1.A.2) 2. Remove existing lot lines "to be abandoned" and keynote 36 from site plan. The site plan shall reflect one consolidated lot boundary with applicable dimensions and bearings. (D.S. 2-02.2.1.A.5) 3. Since carports are to be reviewed under separate permit please remove the carports from the drawing or provide the setback dimension from back of future curb along 6th Avenue to the carport located along the 6th Ave frontage. Minimum setback required is based on the greater of 21 feet or the structure height, measured from back of future curb. (D.S. 2-02.2.1.A.6) (LUC Sec. 3.2.6.5.B.1) 4. Label and dimension future sight visibility triangles. (D.S. 2-02.2.1.A.10) 5. A minimum distance of three (3) feet is required between the back up spur and the proposed wall. The spur must have a wheel barrier to prevent encroachment onto any unsurfaced area. (D.S. 3-05.2.2.D) (D.S. 2-02.2.1.A.11) 6. Keynote 33 not found on site plan. Please remove if not used. 7. If applicable, provide a detail of existing and/or proposed free-standing signs, billboard, and outdoor lighting on the site plan. (D.S. 2-02.2.1.A.13) (D.S. 2-02.2.1.A.25) 8. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference. (D.S. 2-02.2.1.A.20) 9. Provide a copy of the stamped approved HPZ site plan for reference. 10. Under the lot coverage calculation please provide the square footage of the building area and vehicular use area to verify the correct percentage. (D.S. 2-02.2.2.A.3) 11. All requested changes must be made to the site and landscape plans. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 07/13/2004 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal. 2. All lettering and dimensions shall be the equivalent of twelve (0.12") point or greater in size. The purpose of this requirement is to assure that all lettering is legible when reviewed and will maintain that legibility when reproduced and photographically reduced (microfilmed) for record-keeping purposes. D.S. 2-05.2.1.C 3. Indicate contour intervals next to scale and north arrow. This should be placed together. D.S. 2-02.2.1.A.1 4. Indicate property legal description. A lot combination is required before Site Plan approval. D.S. 2-02.2.1.A.2 5. Indicate location map. D.S. 2-02.2.1.A.4 6. Indicate all lot dimensions and bearings as per lot combination. D.S. 2-02.2.1.A.5 7. Indicate and label future sight visibility triangles. D.S. 2-02.2.1.A.10 8. If applicable, indicate location, type, size and height of existing and proposed signage. D.S. 2-02.2.1.A.13 9. Indicate drainage patterns, proposed finish floor elevation(s) and finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16 10. Indicate if street is Public or Private. Closed unused driveways. D.S. 2-02.2.1.A.18 11. If applicable, indicate all easements of record to be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20 12. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. D.S. 2-02.2.1.A.21 13. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.A.23 14. New projects, including mobile home parks, consisting of 3 or more dwelling units will provide centralized on-site refuse storage, collection and pickup areas. Demonstrate vehicle maneuverability fully dimensioned. Indicate a refuse enclosure detail as per D.S. 6-01.4.2 Contact John Clark of Environmental Services @ 791-3175 ext. 1136 to reach an agreement that does not meet Development Standards 6-01 and to obtain a DSMR. 15. The minimum curb return for an arterial street to a PAAL is 25-feet. D.S. 3-01.3.2.C & D.S. 3-01.10.Figure 6 16. Correct text overlays. Drainage Statement 1. Submit a Drainage Statement. Demonstrate flow acceptance/discharge, maintaining existing drainage patterns; preventing street flow from entering building areas. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/27/2004 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 07/27/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |